山东电力技术
山東電力技術
산동전력기술
SHANDONG ELECTRIC POWER
2010年
2期
43-45
,共3页
流化床锅炉%屏式过热器%磨损%数值模拟
流化床鍋爐%屏式過熱器%磨損%數值模擬
류화상과로%병식과열기%마손%수치모의
circulating fluidized bed boiler%plated superheater%wear%numerical simulation
磨损是循环流化床锅炉中最常见的问题,严重制约着锅炉的安全运行。采用CFX软件对某电厂465t/h循环流化床锅炉屏式过热器磨损过程进行了数值模拟,详细分析了磨损原因,指出管屏变形是磨损爆管的主要原因,并针对磨损的原因,提出了相应措施。
磨損是循環流化床鍋爐中最常見的問題,嚴重製約著鍋爐的安全運行。採用CFX軟件對某電廠465t/h循環流化床鍋爐屏式過熱器磨損過程進行瞭數值模擬,詳細分析瞭磨損原因,指齣管屏變形是磨損爆管的主要原因,併針對磨損的原因,提齣瞭相應措施。
마손시순배류화상과로중최상견적문제,엄중제약착과로적안전운행。채용CFX연건대모전엄465t/h순배류화상과로병식과열기마손과정진행료수치모의,상세분석료마손원인,지출관병변형시마손폭관적주요원인,병침대마손적원인,제출료상응조시。
Wear is the most common problem in CFB boiler,which has a great impact on CFB boiler safely operating.Numerical simulating the wearing process of plated superheater in a CFB boiler is proved by CFX program and the result of wear is analyzed.It is concluded that tube failure was caused by wear which was resulted by distortion of plated superheater.Based on the conclusion,further improvement measures are given.