中国医学影像技术
中國醫學影像技術
중국의학영상기술
CHINESE JOURNAL OF MEDICAL IMAGING TECHNOLOGY
2010年
1期
99-103
,共5页
腹膜转移%体层摄影术,发射型计算机%体层摄影术,X线计算机%Meta分析
腹膜轉移%體層攝影術,髮射型計算機%體層攝影術,X線計算機%Meta分析
복막전이%체층섭영술,발사형계산궤%체층섭영술,X선계산궤%Meta분석
Peritoneal metastases%Tomography,emission-computed%Tomography,X-ray computed%Meta analysis
目的 通过Meta分析评价CT、PET、PET/CT对腹膜转移的临床诊断价值.方法 收集2000年1月-2008年5月国内外公开发表的以病理学和(或)手术结果为金标准的关于CT、PET、PET/CT诊断腹膜转移的中英文文献.采用SAS 8.0、Meta-DiSc 1.4、STATA 10.0软件,检验异质性,根据异质性结果选择相应效应模型,计算出汇总灵敏度和汇总特异度,以综合受试者工作特性曲线(SROC)、曲线下面积(AUC)定性、定量评价该诊断方法的准确率.结果 11篇文献符合纳入标准,PET对腹膜转移诊断的汇总特异度最高[0.96(0.91~0.98)],PET/CT的汇总灵敏度最高[0.77(0.67~0.85)],PET、PET/CT和CT的AUC和Q~*分别为0.92、0.85,0.99、0.96,0.91、0.84,PET/CT与CT的AUC值比较差异有统计学意义(Z=2.33,P<0.05).结论 对肿瘤腹膜转移,PET/CT是一种准确性较高的无创性检查方法.
目的 通過Meta分析評價CT、PET、PET/CT對腹膜轉移的臨床診斷價值.方法 收集2000年1月-2008年5月國內外公開髮錶的以病理學和(或)手術結果為金標準的關于CT、PET、PET/CT診斷腹膜轉移的中英文文獻.採用SAS 8.0、Meta-DiSc 1.4、STATA 10.0軟件,檢驗異質性,根據異質性結果選擇相應效應模型,計算齣彙總靈敏度和彙總特異度,以綜閤受試者工作特性麯線(SROC)、麯線下麵積(AUC)定性、定量評價該診斷方法的準確率.結果 11篇文獻符閤納入標準,PET對腹膜轉移診斷的彙總特異度最高[0.96(0.91~0.98)],PET/CT的彙總靈敏度最高[0.77(0.67~0.85)],PET、PET/CT和CT的AUC和Q~*分彆為0.92、0.85,0.99、0.96,0.91、0.84,PET/CT與CT的AUC值比較差異有統計學意義(Z=2.33,P<0.05).結論 對腫瘤腹膜轉移,PET/CT是一種準確性較高的無創性檢查方法.
목적 통과Meta분석평개CT、PET、PET/CT대복막전이적림상진단개치.방법 수집2000년1월-2008년5월국내외공개발표적이병이학화(혹)수술결과위금표준적관우CT、PET、PET/CT진단복막전이적중영문문헌.채용SAS 8.0、Meta-DiSc 1.4、STATA 10.0연건,검험이질성,근거이질성결과선택상응효응모형,계산출회총령민도화회총특이도,이종합수시자공작특성곡선(SROC)、곡선하면적(AUC)정성、정량평개해진단방법적준학솔.결과 11편문헌부합납입표준,PET대복막전이진단적회총특이도최고[0.96(0.91~0.98)],PET/CT적회총령민도최고[0.77(0.67~0.85)],PET、PET/CT화CT적AUC화Q~*분별위0.92、0.85,0.99、0.96,0.91、0.84,PET/CT여CT적AUC치비교차이유통계학의의(Z=2.33,P<0.05).결론 대종류복막전이,PET/CT시일충준학성교고적무창성검사방법.
Objective To assess the value of CT, PET, PET/CT in diagnosis of peritoneal metastases with Meta analysis. Methods Articles of CT, PET or PET/CT on peritoneal metastases published in English or Chinese from Jan 2000 to May 2008 were collected, and histopathological and (or) surgical findings were taken as golden standards. The sensitivity, specificity, summary receiver operating characteristic (SROC) curves, area under the curve (AUC) and the heterogeneity were calculated with software of SAS 8.0, Meta-DiSc 1.4 and STATA 10.0. Results The results of Meta analysis from 11selected articals showed that PET had the highest pooled specificity [0.96, (0.91-0.98)];PET/CT had highest pooled sensitivity [0.77, (0.67-0.85)]. The AUC and Q~* of PET, PET/CT and CT was (0.92, 0.85), (0.99, 0.96), (0.91, 0.84), respectively. AUC of PET/CT was higher than that of CT (Z=2.33, P<0.05). Conclusion PET/CT is a high accuracy diagnostic tool for detecting peritoneal metastases.