针对超临界机组的控制特点,对淮浙煤电有限公司安徽凤台发电分公司<'#>1 600 MW超临界直流机组给水控制工作原理及其控制策略进行了介绍.基于STAR-90仿真平台,通过仿真试验,检验了该控制策略的合理性,为以后国内超临界大型机组给水控制研究提供了借鉴和参考.
針對超臨界機組的控製特點,對淮浙煤電有限公司安徽鳳檯髮電分公司<'#>1 600 MW超臨界直流機組給水控製工作原理及其控製策略進行瞭介紹.基于STAR-90倣真平檯,通過倣真試驗,檢驗瞭該控製策略的閤理性,為以後國內超臨界大型機組給水控製研究提供瞭藉鑒和參攷.
침대초림계궤조적공제특점,대회절매전유한공사안휘봉태발전분공사<'#>1 600 MW초림계직류궤조급수공제공작원리급기공제책략진행료개소.기우STAR-90방진평태,통과방진시험,검험료해공제책략적합이성,위이후국내초림계대형궤조급수공제연구제공료차감화삼고.
Aiming at the features of supercritical unit control, the operation principle and control strategy of feed-water control system in 600 MW No. 1 supercritical one-through boiler of Fengtai Power Generation Branch Office of Huaizhe Cosl-electric Corporation Lim-ited were introduced. Based on the Star- 90 simulation platform, the rationality of the control strategy was verified by simulation ex-periment. The control strategy can be used as reference for feed wa-ter control research of domestic high capacity unit.