目的 比较国产T-free膝关节假体与同类进口假体膝关节置换的早期疗效.方法 2008年7月至2009年12月采用国产T-free膝关节表面假体施行膝关节置换25例35膝,单侧15例、双侧10例;屈曲挛缩19例25膝、内翻畸形11例18膝、外翻畸形4例5膝.膝关节活动度75.11°±27.68°,美国膝关节协会评分系统(Knee Society Score,KSS)膝评分(17.88±14.37)分,KSS功能评分(21.62±21.27)分.同期同一术者施行的同类进口膝关节假体置换27例39膝做为对照进行回顾性研究.两组患者年龄、体重指数、随访时间、术前膝关节活动度的差异无统计学意义;术前KSS膝评分及KSS功能评分的差异有统计学意义.结果 国产假体组24例平均随访(14.92±8.32)个月,与进口假体组26例(15.42±9.87)个月的差异无统计学意义.末次随访时国产假体组的膝关节活动度平均107.53°±18.32°,与进口假体组112.84°±9.76°的差异无统计学意义;KSS膝评分平均(86.71±9.78)分,与进口假体组(86.68±6.01)分的差异无统计学意义;KSS功能评分平均(65.88±25.01)分,与进口假体组(71.35±16.74)分的差异无统计学意义.国产假体组患者的满意率为95.8%(23/24).结论 国产T-free膝关节表面假体与同类进口产品的近期疗效相当.
目的 比較國產T-free膝關節假體與同類進口假體膝關節置換的早期療效.方法 2008年7月至2009年12月採用國產T-free膝關節錶麵假體施行膝關節置換25例35膝,單側15例、雙側10例;屈麯攣縮19例25膝、內翻畸形11例18膝、外翻畸形4例5膝.膝關節活動度75.11°±27.68°,美國膝關節協會評分繫統(Knee Society Score,KSS)膝評分(17.88±14.37)分,KSS功能評分(21.62±21.27)分.同期同一術者施行的同類進口膝關節假體置換27例39膝做為對照進行迴顧性研究.兩組患者年齡、體重指數、隨訪時間、術前膝關節活動度的差異無統計學意義;術前KSS膝評分及KSS功能評分的差異有統計學意義.結果 國產假體組24例平均隨訪(14.92±8.32)箇月,與進口假體組26例(15.42±9.87)箇月的差異無統計學意義.末次隨訪時國產假體組的膝關節活動度平均107.53°±18.32°,與進口假體組112.84°±9.76°的差異無統計學意義;KSS膝評分平均(86.71±9.78)分,與進口假體組(86.68±6.01)分的差異無統計學意義;KSS功能評分平均(65.88±25.01)分,與進口假體組(71.35±16.74)分的差異無統計學意義.國產假體組患者的滿意率為95.8%(23/24).結論 國產T-free膝關節錶麵假體與同類進口產品的近期療效相噹.
목적 비교국산T-free슬관절가체여동류진구가체슬관절치환적조기료효.방법 2008년7월지2009년12월채용국산T-free슬관절표면가체시행슬관절치환25례35슬,단측15례、쌍측10례;굴곡련축19례25슬、내번기형11례18슬、외번기형4례5슬.슬관절활동도75.11°±27.68°,미국슬관절협회평분계통(Knee Society Score,KSS)슬평분(17.88±14.37)분,KSS공능평분(21.62±21.27)분.동기동일술자시행적동류진구슬관절가체치환27례39슬주위대조진행회고성연구.량조환자년령、체중지수、수방시간、술전슬관절활동도적차이무통계학의의;술전KSS슬평분급KSS공능평분적차이유통계학의의.결과 국산가체조24례평균수방(14.92±8.32)개월,여진구가체조26례(15.42±9.87)개월적차이무통계학의의.말차수방시국산가체조적슬관절활동도평균107.53°±18.32°,여진구가체조112.84°±9.76°적차이무통계학의의;KSS슬평분평균(86.71±9.78)분,여진구가체조(86.68±6.01)분적차이무통계학의의;KSS공능평분평균(65.88±25.01)분,여진구가체조(71.35±16.74)분적차이무통계학의의.국산가체조환자적만의솔위95.8%(23/24).결론 국산T-free슬관절표면가체여동류진구산품적근기료효상당.
Objective To compare domestic T-free knee prosthesis with the similar imported prosthesis in preliminary clinical results for early follow-up.Methods From July 2008 to December 2009,35knees of 25 patients were implanted with domestic T-free knee prosthesis,including unilateral TKA in 15 cases and bilateral TKA in 10.Deformity included flexion contracture in 19 cases with 25 knees,varus deformity in 11 with 18 knees,valgus deformity in 4 with 5 knees.The preoperative average ROM was 75.11°±27.68°,the mean points of Knee Society Score(KSS)were 17.88±14.37,and the average points of KSS function scores were 21.62±21.27.In the same period,all 27 cases with 39 knees operated by the same surgeon were implanted the similar imported prosthesis,and they were set for control group to do the retrospective cohort study.The patients of two groups who completed follow up had no statistical differences in age,BMI and preoperation ROM(P>0.05),but they had statistical differences in pre-operation KSS scores and pre-operation KSS function scores(P<0.05).Results The domestic prosthesis group's average follow-up time were 14.92±8.32 months and had no statistically different with the control group's 15.42±9.87 months(P>0.05).The mean postoperation knee ROM of domestic knee prosthesis group was 107.53°±18.32° in 14.92±8.32months follow-up,which did not differ with that of the imported group 112.84°±9.76°(P>0.05).There was no statistical difference in KSS scores between the domestic 86.71 ±9.78 and the imported group 86.68±6.01,and no difference in KSS functional scores was found between the domestic 65.88±25.01 and the imported knee prosthesis 71.35±16.74(P>0.05).The satisfaction rate after TKA was 95.8%(23/24)in domestic knee prosthesis group.Conclusion The domestic T-free knee prosthesis was commensurate with the similar imported knee prosthesis in preliminary clinical results for early follow-up.