对双曲线自然通风冷却塔的传热原理和配水系统进行了介绍,分析了冷却塔冬季运行结冰的部位和原因,结合生产实践详细阐述了防止结冰的各种有效措施。
對雙麯線自然通風冷卻塔的傳熱原理和配水繫統進行瞭介紹,分析瞭冷卻塔鼕季運行結冰的部位和原因,結閤生產實踐詳細闡述瞭防止結冰的各種有效措施。
대쌍곡선자연통풍냉각탑적전열원리화배수계통진행료개소,분석료냉각탑동계운행결빙적부위화원인,결합생산실천상세천술료방지결빙적각충유효조시。
The heat transmission principle and the water distributing system of the hyperbolic natural draft cooling tower were introduced.The freeze positions and freeze reason of the cooling tower in winter operation were analyzed.Combining with the production practice,various effective measures to prevent freeze were expounded.