目的 探索肺动脉三维血管成像多层螺旋CT低剂量扫描的可行性,以及肺动脉容积三维处理(VR)图像的质量与平扫SD值的关系.方法 选取行肺动脉CT检查的受检者87人.选取志愿者63人为低剂量组,其余24人采用常规剂量扫描作为常规组.两者平扫均采用常规剂量150 mAs,低剂量肺动脉增强扫描采用60 mAs.图像进行VR后处理后,按A、B、C 3个等级进行评定,两组VR图像进行质量等级比较.低剂量组平扫图像测量CT值的标准差SD值,与增强的VR图像质量等级关系进行受试者操作特性曲线(ROC)分析.结果 常规剂量组VR图像等级为A级的达到100%,在低剂量组VR图像等级为A级的达到85.7%.平扫SD值与肺动脉VR图像的质量相关性分析,ROC曲线下面积为0.906.结论 肺动脉三维血管成像的低剂量扫描切实可行.
目的 探索肺動脈三維血管成像多層螺鏇CT低劑量掃描的可行性,以及肺動脈容積三維處理(VR)圖像的質量與平掃SD值的關繫.方法 選取行肺動脈CT檢查的受檢者87人.選取誌願者63人為低劑量組,其餘24人採用常規劑量掃描作為常規組.兩者平掃均採用常規劑量150 mAs,低劑量肺動脈增彊掃描採用60 mAs.圖像進行VR後處理後,按A、B、C 3箇等級進行評定,兩組VR圖像進行質量等級比較.低劑量組平掃圖像測量CT值的標準差SD值,與增彊的VR圖像質量等級關繫進行受試者操作特性麯線(ROC)分析.結果 常規劑量組VR圖像等級為A級的達到100%,在低劑量組VR圖像等級為A級的達到85.7%.平掃SD值與肺動脈VR圖像的質量相關性分析,ROC麯線下麵積為0.906.結論 肺動脈三維血管成像的低劑量掃描切實可行.
목적 탐색폐동맥삼유혈관성상다층라선CT저제량소묘적가행성,이급폐동맥용적삼유처리(VR)도상적질량여평소SD치적관계.방법 선취행폐동맥CT검사적수검자87인.선취지원자63인위저제량조,기여24인채용상규제량소묘작위상규조.량자평소균채용상규제량150 mAs,저제량폐동맥증강소묘채용60 mAs.도상진행VR후처리후,안A、B、C 3개등급진행평정,량조VR도상진행질량등급비교.저제량조평소도상측량CT치적표준차SD치,여증강적VR도상질량등급관계진행수시자조작특성곡선(ROC)분석.결과 상규제량조VR도상등급위A급적체도100%,재저제량조VR도상등급위A급적체도85.7%.평소SD치여폐동맥VR도상적질량상관성분석,ROC곡선하면적위0.906.결론 폐동맥삼유혈관성상적저제량소묘절실가행.
Objective To explore the feasibility of low-dose multi-slice computed tomography(MSCT) scan on pulmonary artery three-dimensional angiography, and the relationship between pulmonary VR image quality and the SD value of plain scan. Methods Pulmonary artery CT examination was performed in 87 patients. 63 volunteers were administered with low dose as a low-dose group, and the other 24 were scanned with conventional dose as a routine group. Both plain scans were use conventional dose of pulmonary scan with 150 mAs, and the low-dose pulmonary enhanced scans were used with 60 mAs. The images were post-processed with volume rendering(VR) and classified into three grades A, B and C, and VR image quality levels of both groups compared. The receiver operating characteristic curve( ROC) was used to analyze the relationship between VR image quality level and SD value of plain scan image SD value. Results The VR image level of A-class was 100% in the conventional dose group, and 85. 7% was in the low dose group . According to the correlation analysis between the standard deviation(SD) value of plain scan image and pulmonary artery VR image quality, the area under curve in receiver-operated characteristic analysis was 0. 906. Conclusions The low-dose scan of pulmonary artery three-dimensional angiography is feasible. Using 60 mAs low-dose in pulmonary artery enhanced scan could ensure better image quality. With the SD value of the plain scan decreased, the pulmonary artery VR image quality is improved.