中华口腔医学杂志
中華口腔醫學雜誌
중화구강의학잡지
Chinese Journal of Stomatology
2008年
7期
431-433
,共3页
陈岩%ZHAO Wen-ting%Hee-Moon Kyung
陳巖%ZHAO Wen-ting%Hee-Moon Kyung
진암%ZHAO Wen-ting%Hee-Moon Kyung
组织学%种植体支抗%骨结合
組織學%種植體支抗%骨結閤
조직학%충식체지항%골결합
Histology%Implant anchorage%Osseointegration
目的 通过比较助攻法和自攻法植入的即刻负载正畸种植体的骨结合情况,评价不同种植方法对种植体及周围组织的影响. 方法 以3只犬的最后一颗前磨牙与第一磨牙根间区、第一磨牙近远中根根分歧的颊侧为植入点,植入24枚正畸种植体;每只犬植入8枚,自攻法(自攻组)植入4枚,助攻法(助攻组)植入4枚.镍钛弹簧即刻提供1.47~1.96 N水平力,持续9周.光学显微镜和荧光显微镜评价种植体周围骨组织的变化和骨结合率. 结果 两组种植体均与骨组织形成骨结合,其间未见结缔组织.自攻组可见较多的陈旧骨,助攻组的骨生长和再生更活跃.自攻组种植体的骨结合率[(41.7±10.7)%]高于助攻组[(25.9±8.0)%],差异有统计学意义(P<0.01). 结论 即刻负载不影响正畸种植体的骨结合.自攻法对骨组织损伤小,且骨结合率高于助攻组.
目的 通過比較助攻法和自攻法植入的即刻負載正畸種植體的骨結閤情況,評價不同種植方法對種植體及週圍組織的影響. 方法 以3隻犬的最後一顆前磨牙與第一磨牙根間區、第一磨牙近遠中根根分歧的頰側為植入點,植入24枚正畸種植體;每隻犬植入8枚,自攻法(自攻組)植入4枚,助攻法(助攻組)植入4枚.鎳鈦彈簧即刻提供1.47~1.96 N水平力,持續9週.光學顯微鏡和熒光顯微鏡評價種植體週圍骨組織的變化和骨結閤率. 結果 兩組種植體均與骨組織形成骨結閤,其間未見結締組織.自攻組可見較多的陳舊骨,助攻組的骨生長和再生更活躍.自攻組種植體的骨結閤率[(41.7±10.7)%]高于助攻組[(25.9±8.0)%],差異有統計學意義(P<0.01). 結論 即刻負載不影響正畸種植體的骨結閤.自攻法對骨組織損傷小,且骨結閤率高于助攻組.
목적 통과비교조공법화자공법식입적즉각부재정기충식체적골결합정황,평개불동충식방법대충식체급주위조직적영향. 방법 이3지견적최후일과전마아여제일마아근간구、제일마아근원중근근분기적협측위식입점,식입24매정기충식체;매지견식입8매,자공법(자공조)식입4매,조공법(조공조)식입4매.얼태탄황즉각제공1.47~1.96 N수평력,지속9주.광학현미경화형광현미경평개충식체주위골조직적변화화골결합솔. 결과 량조충식체균여골조직형성골결합,기간미견결체조직.자공조가견교다적진구골,조공조적골생장화재생경활약.자공조충식체적골결합솔[(41.7±10.7)%]고우조공조[(25.9±8.0)%],차이유통계학의의(P<0.01). 결론 즉각부재불영향정기충식체적골결합.자공법대골조직손상소,차골결합솔고우조공조.
Objective To investigate the osteointegration of with self-drilling and self-tapping microscrew implants under immediate loading histomorphometrically. Methods The buccal side of upper and lower jaws of three dogs was chosen as implant receipt site. Each dog accepted 8 implants (4 self-drilling and 4 self-tapping implants). Approximately 1.47-1.96 N continuous and constant forces were immediately applied between two microscrew implants with nickel-titanium coll spring for 9 weeks. Undecalcified sections of implants and surrounding tissue were studied with light microscope and fluorescent microscope. Results Osteointegration was seen in all samples and no fibrous tissue was seen between bone and implant. More original bone was seen in self-drilling group. Modeling and remodeling were more active in self-tapping group. Bone-to-implant contact values were statistically significant higher in self-drilling group[(41.7±10.7)%]than in self-tapping group[(25.9±8.0)%,P<0.01]. Conclusions Immediate loading had no influence on osteointegration in both serf-drilling and self-tapping groups. The rates of bone-to-implant contact were higher in self-drilling group.