将2030CAPL炉辐射管烧嘴由一段燃烧改造为两段燃烧,并对烧嘴的各项性能进行了试验,结果表明,新型低NOX烧嘴的NOX的排放量为35×10-6,比引进的烧嘴低22×10-6,而烧嘴的其它性能均获得满意的结果。
將2030CAPL爐輻射管燒嘴由一段燃燒改造為兩段燃燒,併對燒嘴的各項性能進行瞭試驗,結果錶明,新型低NOX燒嘴的NOX的排放量為35×10-6,比引進的燒嘴低22×10-6,而燒嘴的其它性能均穫得滿意的結果。
장2030CAPL로복사관소취유일단연소개조위량단연소,병대소취적각항성능진행료시험,결과표명,신형저NOX소취적NOX적배방량위35×10-6,비인진적소취저22×10-6,이소취적기타성능균획득만의적결과。
The burner of the 2030CAPL furnace radiant tubes was remodeled from one burning zone to two burning zones and some experiments was taken to examining the characteristic of it. The results show that the measure of NOX in the let gas of the new burner is 35ppm and 22ppm lower than that of the import burner. All the characteristics of the burner are good for its application.