目的 制备一种载重组腺病毒的脂质超声微泡造影剂,对其物理特性、载病毒的能力及在兔肝脏的显影效果进行研究.方法 采用机械振荡法及分层吸附法制备一种载重组腺病毒Ad-EGFP/HIF-1α的脂质超声微泡造影剂,用DFY-Ⅱ型超声图像定量分析诊断仪检测微泡粒径和浓度;检测其结合腺病毒的能力及观察对正常兔肝脏的显影效果.结果 载重组腺病毒Ad-EGFP/HIF-1α的超声微泡分布均匀,平均粒径为(1.17±0.82)μm,浓度为(2.50±0.12)×10~9/mL;该造影剂的最大腺病毒结合的效率为30%;体内造影显示该造影剂能够有效增强兔肝脏实质回声.结论 自制载重组腺病毒的微泡造影剂符合理想超声造影剂的要求,性质稳定,制备简易,载腺病毒效率高,为超声靶向微泡破裂基因释放技术的发展开辟新思路.
目的 製備一種載重組腺病毒的脂質超聲微泡造影劑,對其物理特性、載病毒的能力及在兔肝髒的顯影效果進行研究.方法 採用機械振盪法及分層吸附法製備一種載重組腺病毒Ad-EGFP/HIF-1α的脂質超聲微泡造影劑,用DFY-Ⅱ型超聲圖像定量分析診斷儀檢測微泡粒徑和濃度;檢測其結閤腺病毒的能力及觀察對正常兔肝髒的顯影效果.結果 載重組腺病毒Ad-EGFP/HIF-1α的超聲微泡分佈均勻,平均粒徑為(1.17±0.82)μm,濃度為(2.50±0.12)×10~9/mL;該造影劑的最大腺病毒結閤的效率為30%;體內造影顯示該造影劑能夠有效增彊兔肝髒實質迴聲.結論 自製載重組腺病毒的微泡造影劑符閤理想超聲造影劑的要求,性質穩定,製備簡易,載腺病毒效率高,為超聲靶嚮微泡破裂基因釋放技術的髮展開闢新思路.
목적 제비일충재중조선병독적지질초성미포조영제,대기물리특성、재병독적능력급재토간장적현영효과진행연구.방법 채용궤계진탕법급분층흡부법제비일충재중조선병독Ad-EGFP/HIF-1α적지질초성미포조영제,용DFY-Ⅱ형초성도상정량분석진단의검측미포립경화농도;검측기결합선병독적능력급관찰대정상토간장적현영효과.결과 재중조선병독Ad-EGFP/HIF-1α적초성미포분포균균,평균립경위(1.17±0.82)μm,농도위(2.50±0.12)×10~9/mL;해조영제적최대선병독결합적효솔위30%;체내조영현시해조영제능구유효증강토간장실질회성.결론 자제재중조선병독적미포조영제부합이상초성조영제적요구,성질은정,제비간역,재선병독효솔고,위초성파향미포파렬기인석방기술적발전개벽신사로.
Objective To prepare the lipid ultrasound microbubbles carrying recombinant adenovirus and to study the efficiency of carrying recombinant adenovirus as well as their ability as an ultrasound contrast agent.Methods The lipid ultrasound microbubbles carriying with recombinant adenovirus were prepared using mechanical vibration method and stratified absorption method.The diameter and concentration of microbubbles were determined by DFY-Ⅱ software.The efficiencies of carrying recombinant adenovirus were investigated by aconfocal laser scanning microscopy and a fluorospectrophotometer.In vivo experiment was performed on rabbits to observe the duration and intensity of enhancement in the liver after the injection of the microbubbles.Results The diameter of the lipid microbubbles carrying recombinant adenovirus was(1.17±0.82)μm and the concentration was(2.50±0.12)×10~9/mL.The recombinant adenovirus encapsulation efficiency of the lipid ultrasound microbubbles was 30%.The experiment showed that the microbubbles could significantly enhance the echo intensity of liver.Conclusions The efficiency of carrying recombinant adenovirus of the prepared microbubbles is high,which can be used as a new vehicle carrying genes or drugs in therapy and as an ultrasound contrast agent,which may be chosen as an ideal ultrasound contrast agent in future.