郑蕤%肖湘宁%郭春林%高本锋
鄭蕤%肖湘寧%郭春林%高本鋒
정유%초상저%곽춘림%고본봉
测试信号法%交直流系统%高压直流输电%可控串联补偿%次同步振荡
測試信號法%交直流繫統%高壓直流輸電%可控串聯補償%次同步振盪
측시신호법%교직류계통%고압직류수전%가공천련보상%차동보진탕
test signal method%AC/DC power grid%HVDC power transmission%thyristor controlled series compensation (TCSC)%subsynchronous oscillation (SSO)
建立了基于伊冯/呼辽交直流系统的电磁暂态模型,采用基于时域仿真实现的复转矩系数法——测试信号法,对机组施加了一系列不同频率的测试信号。计算了不同连接方式下机组在次同步频率范围内的电气阻尼特性,并考察了可控串联补偿装置对该阻尼特性的影响。最后结合时域仿真法验证了测试信号法分析结果的有效性。理论分析和仿真结果表明,在交直流系统中采用联网运行带可控串补的方式,有利于抑制高压直流输电系统和交流输电线路中串补装置引起的次同步振荡问题。
建立瞭基于伊馮/呼遼交直流繫統的電磁暫態模型,採用基于時域倣真實現的複轉矩繫數法——測試信號法,對機組施加瞭一繫列不同頻率的測試信號。計算瞭不同連接方式下機組在次同步頻率範圍內的電氣阻尼特性,併攷察瞭可控串聯補償裝置對該阻尼特性的影響。最後結閤時域倣真法驗證瞭測試信號法分析結果的有效性。理論分析和倣真結果錶明,在交直流繫統中採用聯網運行帶可控串補的方式,有利于抑製高壓直流輸電繫統和交流輸電線路中串補裝置引起的次同步振盪問題。
건립료기우이풍/호료교직류계통적전자잠태모형,채용기우시역방진실현적복전구계수법——측시신호법,대궤조시가료일계렬불동빈솔적측시신호。계산료불동련접방식하궤조재차동보빈솔범위내적전기조니특성,병고찰료가공천련보상장치대해조니특성적영향。최후결합시역방진법험증료측시신호법분석결과적유효성。이론분석화방진결과표명,재교직류계통중채용련망운행대가공천보적방식,유리우억제고압직류수전계통화교류수전선로중천보장치인기적차동보진탕문제。
An electromagnetic transient model for AC/DC power grid consisting of 500 kV AC power transmission from Yimin to Fengtun and ±500 kV DC power transmission from Hulun Buir to Liaoning is built, and adopting the complex torque coefficient method-test signal method that is implemented by time-domain simulation a series of testing signals with different frequencies are applied to generation units. Generation units’ electrical damping characteristics within the frequency range of subsynchronous oscillation (SSO) under different wiring patterns are calculated, and the influence of TCSC on the damping characteristics is observed. Based on time-domain simulation, the effectiveness of analysis results by test signal method is verified. Both results from theoretical analysis and experimental verification show that in AC/DC power grid the connected operation of DC power system with AC power system is favorable to mitigate SSO caused by HVDC power transmission system and serial compensation equipments in AC power transmission system.