实验流体力学
實驗流體力學
실험류체역학
JOURNAL OF EXPERIMENTS IN FLUID MECHANICS
2010年
1期
84-88
,共5页
李彦梅%徐英%张三刚%郭玉%江善和
李彥梅%徐英%張三剛%郭玉%江善和
리언매%서영%장삼강%곽옥%강선화
内锥流量计%上游弯头%流出系数%雷诺数%计算流体动力学
內錐流量計%上遊彎頭%流齣繫數%雷諾數%計算流體動力學
내추류량계%상유만두%류출계수%뢰낙수%계산류체동역학
V-cone flowmeter%upstream elbow%discharge coefficient%Reynolds number%com-putational flow dynamics
研究旨在获取上游弯头安装条件下内锥流量计的性能和所需要的直管段长度.研制了100mm口径、β值分别为0. 45、0. 65、0. 85三种结构类型的样机.开展了上游单弯头、同一平面上连续两个90°成S型结构双弯头及互成垂直平面上连续两个90°双弯头的仿真和实验研究,仿真和实验的介质均为常温水,雷诺数范围分别为0. 498×10~5~4. 98×10~5和0. 14×10~5~4. 5×10~5.仿真结果与实验结论一致,并利用平均流出系数相对误差及附加不确定度作为安装条件影响的主要评价标准.给出了上游弯头安装条件内锥流量计所需的直管段长度.
研究旨在穫取上遊彎頭安裝條件下內錐流量計的性能和所需要的直管段長度.研製瞭100mm口徑、β值分彆為0. 45、0. 65、0. 85三種結構類型的樣機.開展瞭上遊單彎頭、同一平麵上連續兩箇90°成S型結構雙彎頭及互成垂直平麵上連續兩箇90°雙彎頭的倣真和實驗研究,倣真和實驗的介質均為常溫水,雷諾數範圍分彆為0. 498×10~5~4. 98×10~5和0. 14×10~5~4. 5×10~5.倣真結果與實驗結論一緻,併利用平均流齣繫數相對誤差及附加不確定度作為安裝條件影響的主要評價標準.給齣瞭上遊彎頭安裝條件內錐流量計所需的直管段長度.
연구지재획취상유만두안장조건하내추류량계적성능화소수요적직관단장도.연제료100mm구경、β치분별위0. 45、0. 65、0. 85삼충결구류형적양궤.개전료상유단만두、동일평면상련속량개90°성S형결구쌍만두급호성수직평면상련속량개90°쌍만두적방진화실험연구,방진화실험적개질균위상온수,뢰낙수범위분별위0. 498×10~5~4. 98×10~5화0. 14×10~5~4. 5×10~5.방진결과여실험결론일치,병이용평균류출계수상대오차급부가불학정도작위안장조건영향적주요평개표준.급출료상유만두안장조건내추류량계소수적직관단장도.
In order to acquire the shortest straight pipe length and investigate the performance of cone flowmeter with installed upstream elbow, this study has put forward three different structure prototypes with lOOmm diameters and the p values being 0.45. 0.65. 0.85 respectively. Simulation and experiment investigations have been carried out with the installment of a upstream single 90o elbow, double closed 90o elbows of "S" shape under the same plane and double closed 90oelbows under the vertical plane, with the medium of normal temperature water and Reynolds numbers being 0.498 × 10~5 ~4.98 × 10~5 and 0.14 × 10~5 ~4.5 × 10~5 respectively. The numerical simulation result is consistent with the experimental conclusion. Through both of them, we ob-tain the length of the straight pipe for the cone flowmeter while the effects of the relative error and additive uncertainty of the averaged discharge coefficient on the installation of upstream el-bow have been considered.