为了研究油罐在着火时的温度分布情况,进行了直径分别为1.0 m,1.5 m和2.7 m三种尺寸的油罐火灾实验.在实验中,分别测量火焰,罐壁和深层不燃烧油品的温度,分析和研究了着火油罐的温度分布.
為瞭研究油罐在著火時的溫度分佈情況,進行瞭直徑分彆為1.0 m,1.5 m和2.7 m三種呎吋的油罐火災實驗.在實驗中,分彆測量火燄,罐壁和深層不燃燒油品的溫度,分析和研究瞭著火油罐的溫度分佈.
위료연구유관재착화시적온도분포정황,진행료직경분별위1.0 m,1.5 m화2.7 m삼충척촌적유관화재실험.재실험중,분별측량화염,관벽화심층불연소유품적온도,분석화연구료착화유관적온도분포.
To understand the temperature distribution of oil tank fires,several sizes of oil tank fires were conducted. The diameter of the tanks are 1 m,1.5 m and 2.7 m respectively. The temperature of tanks and flames were measured to analyze and study the temperature distribution of oil tank fires.