空鼓是西藏古建筑壁画中普遍存在的严重病害,空鼓壁画约占病害壁画总面积的75%以上.基于定量化评价壁画空鼓现象及其修复效果,利用探地雷达探测布达拉宫西大殿南壁壁画空鼓区的分布情况,并分析空鼓区电磁波反射特征.利用一定模数和浓度的PS材料对探测的壁画空鼓区进行灌浆加固处理,在经过1 a的养护期后,再次利用探地雷达对加固的壁画区进行检测.检测结果显示,在未灌浆加固前块石墙体的反射信号较为强烈,加固后检测不出因空鼓而在层与层之间产生的电磁波反射信号,空鼓部位已经被灌浆材料紧密地黏结成一体.分析结果表明,PS材料灌浆技术可以有效治理壁画空鼓现象,利用探地雷达能够准确检测壁画空鼓状况及修复效果.
空鼓是西藏古建築壁畫中普遍存在的嚴重病害,空鼓壁畫約佔病害壁畫總麵積的75%以上.基于定量化評價壁畫空鼓現象及其脩複效果,利用探地雷達探測佈達拉宮西大殿南壁壁畫空鼓區的分佈情況,併分析空鼓區電磁波反射特徵.利用一定模數和濃度的PS材料對探測的壁畫空鼓區進行灌漿加固處理,在經過1 a的養護期後,再次利用探地雷達對加固的壁畫區進行檢測.檢測結果顯示,在未灌漿加固前塊石牆體的反射信號較為彊烈,加固後檢測不齣因空鼓而在層與層之間產生的電磁波反射信號,空鼓部位已經被灌漿材料緊密地黏結成一體.分析結果錶明,PS材料灌漿技術可以有效治理壁畫空鼓現象,利用探地雷達能夠準確檢測壁畫空鼓狀況及脩複效果.
공고시서장고건축벽화중보편존재적엄중병해,공고벽화약점병해벽화총면적적75%이상.기우정양화평개벽화공고현상급기수복효과,이용탐지뢰체탐측포체랍궁서대전남벽벽화공고구적분포정황,병분석공고구전자파반사특정.이용일정모수화농도적PS재료대탐측적벽화공고구진행관장가고처리,재경과1 a적양호기후,재차이용탐지뢰체대가고적벽화구진행검측.검측결과현시,재미관장가고전괴석장체적반사신호교위강렬,가고후검측불출인공고이재층여층지간산생적전자파반사신호,공고부위이경피관장재료긴밀지점결성일체.분석결과표명,PS재료관장기술가이유효치리벽화공고현상,이용탐지뢰체능구준학검측벽화공고상황급수복효과.
The detachment is one of the most critical diseases of ancient architecture murals at Tibet,and the area of detachment murals make up more than seventy-five percent of the total area of diseases murals. Based on working out measurable evaluation for the phenomenon of detachment murals and its repairing effect,the distribution of detachment murals were detected by ground-penetrating radar at the Potala palace,furthermore the reflection characters of electromagnetic wave were analyzed in detachment murals. For the detachment murals,PS materials of some moduli and concentrations were grouted into the detachment area. During one year for maintenance,the distribution of the detachment murals was detected by ground-penetrating radar again. It shows that the reflection signals of electromagnetic wave are strong in the stone-wall before grouting the detachment area,but after grouting the detachment area,it can not be detected between layers due to the detachment area felted for whole by PS material. It indicates that the grouting technology of PS material can effectively repair the detachment murals,and ground-penetrating radar can accurately improve the status of detachment and its repairing effect.