为对混凝/Fenton工艺与Fenton/混凝工艺处理垃圾渗滤液的效果和成本进行比较,分别对年轻渗滤液和老龄渗滤液原液按照混凝/Fenton工艺与Fenton/混凝工艺2种技术路线进行处理.实验结果表明,Fenton试剂对年轻垃圾渗滤液和老龄垃圾渗滤液COD去除率最高的反应条件为pH=3.5、H_2O_2和Fe~(2+)的摩尔比为6、H_2O_2和渗滤液原液的COD质量比为3、反应时间4 h;在PAC与渗滤液原液的COD质量比为0.6时,PAC混凝对渗滤液原液的COD去除率最高.在对渗滤液COD去除率最高的Fenton反应和PAC混凝反应条件下,混凝/Fenton工艺对年轻渗滤液和老龄渗滤液的COD去除率分别为90.56%和86.56%;Fenton/混凝工艺对年轻渗滤液和老龄渗滤液的COD去除率分别为89.99%和85.99%,2种技术路线对渗滤液COD的去除率相差不大,但先PAC混凝后Fenton氧化工艺比先Fenton后混凝工艺每t节省62.6元,是更优化的渗滤液处理工艺.
為對混凝/Fenton工藝與Fenton/混凝工藝處理垃圾滲濾液的效果和成本進行比較,分彆對年輕滲濾液和老齡滲濾液原液按照混凝/Fenton工藝與Fenton/混凝工藝2種技術路線進行處理.實驗結果錶明,Fenton試劑對年輕垃圾滲濾液和老齡垃圾滲濾液COD去除率最高的反應條件為pH=3.5、H_2O_2和Fe~(2+)的摩爾比為6、H_2O_2和滲濾液原液的COD質量比為3、反應時間4 h;在PAC與滲濾液原液的COD質量比為0.6時,PAC混凝對滲濾液原液的COD去除率最高.在對滲濾液COD去除率最高的Fenton反應和PAC混凝反應條件下,混凝/Fenton工藝對年輕滲濾液和老齡滲濾液的COD去除率分彆為90.56%和86.56%;Fenton/混凝工藝對年輕滲濾液和老齡滲濾液的COD去除率分彆為89.99%和85.99%,2種技術路線對滲濾液COD的去除率相差不大,但先PAC混凝後Fenton氧化工藝比先Fenton後混凝工藝每t節省62.6元,是更優化的滲濾液處理工藝.
위대혼응/Fenton공예여Fenton/혼응공예처리랄급삼려액적효과화성본진행비교,분별대년경삼려액화노령삼려액원액안조혼응/Fenton공예여Fenton/혼응공예2충기술로선진행처리.실험결과표명,Fenton시제대년경랄급삼려액화노령랄급삼려액COD거제솔최고적반응조건위pH=3.5、H_2O_2화Fe~(2+)적마이비위6、H_2O_2화삼려액원액적COD질량비위3、반응시간4 h;재PAC여삼려액원액적COD질량비위0.6시,PAC혼응대삼려액원액적COD거제솔최고.재대삼려액COD거제솔최고적Fenton반응화PAC혼응반응조건하,혼응/Fenton공예대년경삼려액화노령삼려액적COD거제솔분별위90.56%화86.56%;Fenton/혼응공예대년경삼려액화노령삼려액적COD거제솔분별위89.99%화85.99%,2충기술로선대삼려액COD적거제솔상차불대,단선PAC혼응후Fenton양화공예비선Fenton후혼응공예매t절성62.6원,시경우화적삼려액처리공예.
In order to compare treatment effect and costs of coagulation/Fenton process and Fenton/coagulation process on leachate treatment,young leachate and old leachate were separately treated by the two techniques.The experimental results indicate that highest COD removal of Fenton reaction on leachate can be acquired under the conditions of pH=3.5,nH_2O_2/nFe~(2+)=6,mH_2O_2/mCOD=3,reaction time=4 hours.The experimental results also indicate that PAC coagulation has the highest COD removal on leachate under the condition of mPAC/mCOD=0.6.Under the optimum reaction conditions,coagulation/Fenton process and Fenton/coagulation process were separately adopted to treat raw leachate.The experimental results indicate that COD removal of coagulation/Fenton process on the young leachate and the old leachate are 90.56%and 86.56%separately;COD removal of Fenton/coagulation process on the young leachate and the old leachate are 89.99%and 85.99%separately,no obvious difference. But the cost of coagulation/Fenton process for leachate treatment is lower 62.6 yuan/t than the cost of Fenton/coagulation process at least;therefore,coagulation/Fenton process is more optimized than Fenton/coagulation process for leachate treatment.