通过对进入"U"型管换热器的气体建立数学模型,计算换热器隔板受力情况,总结损坏换热器的各种因素,避免换热器挡板受力超负荷,保证装置的安全稳定运行。
通過對進入"U"型管換熱器的氣體建立數學模型,計算換熱器隔闆受力情況,總結損壞換熱器的各種因素,避免換熱器擋闆受力超負荷,保證裝置的安全穩定運行。
통과대진입"U"형관환열기적기체건립수학모형,계산환열기격판수력정황,총결손배환열기적각충인소,피면환열기당판수력초부하,보증장치적안전은정운행。
By establishing a mathematical model for the gas flowing into "U-tube" heat-exchanger,the force acted on the exchanger bulkhead is calculated and the various factors causing the damages to the exchanger are summarized to avoid an overloaded force from acting on the bulkhead and to ensure a safe and stable running.