中华器官移植杂志
中華器官移植雜誌
중화기관이식잡지
CHINESE JOURNAL OF ORGAN TRANSPLANTATION
2011年
2期
108-111
,共4页
龚必焱%季倩%龙淼淼%沈文%祁吉
龔必焱%季倩%龍淼淼%瀋文%祁吉
공필염%계천%룡묘묘%침문%기길
肝移植%活体供者%肝体积%体层摄影术,螺旋计算机
肝移植%活體供者%肝體積%體層攝影術,螺鏇計算機
간이식%활체공자%간체적%체층섭영술,라선계산궤
Liver transplantation%Living donors%Liver volume%Tomography,spiral computed
目的 探讨多层螺旋CT(MSCT)半自动法测量右半供肝体积的准确性,及该方法在活体肝移植(LDLT)中的应用价值.方法 对56例供者术前行MSCT四期增强扫描,然后分别根据MSCT图像手动绘图(简称:手动法)计算右半供肝体积(V手)和应用IQQA(R)-liver肝脏诊断辅助分析系统进行半自动化绘图(简称:半自动法)计算右半供肝体积(V半),将两种方法计算的右半供肝体积与术中经水置换法实测的右半供肝体积(V术)进行相关分析和Bland-Altman检查,得出其线性回归方程.结果 V半、V手和V术分别为(818.60±161.43)、(880.16±169.92)和(669.84±141.37)cm3;半自动法和手动法测量供肝体积与术中实测肝体积均显著相关(r值分别为0.778和0.746,P<0.05),其线性回归方程分别为V术=V半×0.681+112.26,V术=V手×0.620+123.81.半自动法测量肝体积与术中实测肝体积的差值为148.76cm3,95%可信区间为121.57~175.95 cm3,吻合限为-354.135~56.62 cm3,手动法测量肝体积与术中实测肝体积的差值为210.33 cm3,95%可信区间为180.09~240.56 cm3,吻合限为-438.66~18.01cm3.结论 半自动法测量LDLT右半供肝体积比目前最常用的手动法更为准确.
目的 探討多層螺鏇CT(MSCT)半自動法測量右半供肝體積的準確性,及該方法在活體肝移植(LDLT)中的應用價值.方法 對56例供者術前行MSCT四期增彊掃描,然後分彆根據MSCT圖像手動繪圖(簡稱:手動法)計算右半供肝體積(V手)和應用IQQA(R)-liver肝髒診斷輔助分析繫統進行半自動化繪圖(簡稱:半自動法)計算右半供肝體積(V半),將兩種方法計算的右半供肝體積與術中經水置換法實測的右半供肝體積(V術)進行相關分析和Bland-Altman檢查,得齣其線性迴歸方程.結果 V半、V手和V術分彆為(818.60±161.43)、(880.16±169.92)和(669.84±141.37)cm3;半自動法和手動法測量供肝體積與術中實測肝體積均顯著相關(r值分彆為0.778和0.746,P<0.05),其線性迴歸方程分彆為V術=V半×0.681+112.26,V術=V手×0.620+123.81.半自動法測量肝體積與術中實測肝體積的差值為148.76cm3,95%可信區間為121.57~175.95 cm3,吻閤限為-354.135~56.62 cm3,手動法測量肝體積與術中實測肝體積的差值為210.33 cm3,95%可信區間為180.09~240.56 cm3,吻閤限為-438.66~18.01cm3.結論 半自動法測量LDLT右半供肝體積比目前最常用的手動法更為準確.
목적 탐토다층라선CT(MSCT)반자동법측량우반공간체적적준학성,급해방법재활체간이식(LDLT)중적응용개치.방법 대56례공자술전행MSCT사기증강소묘,연후분별근거MSCT도상수동회도(간칭:수동법)계산우반공간체적(V수)화응용IQQA(R)-liver간장진단보조분석계통진행반자동화회도(간칭:반자동법)계산우반공간체적(V반),장량충방법계산적우반공간체적여술중경수치환법실측적우반공간체적(V술)진행상관분석화Bland-Altman검사,득출기선성회귀방정.결과 V반、V수화V술분별위(818.60±161.43)、(880.16±169.92)화(669.84±141.37)cm3;반자동법화수동법측량공간체적여술중실측간체적균현저상관(r치분별위0.778화0.746,P<0.05),기선성회귀방정분별위V술=V반×0.681+112.26,V술=V수×0.620+123.81.반자동법측량간체적여술중실측간체적적차치위148.76cm3,95%가신구간위121.57~175.95 cm3,문합한위-354.135~56.62 cm3,수동법측량간체적여술중실측간체적적차치위210.33 cm3,95%가신구간위180.09~240.56 cm3,문합한위-438.66~18.01cm3.결론 반자동법측량LDLT우반공간체적비목전최상용적수동법경위준학.
Objective To evaluate the accuracy of multi-detector spiral CT (MSCT) semiautomated volumetric measurement of right lobes and its value in living donor liver transplantation (LDLT). Methods Fifty-six donors underwent four phases MSCT. Pre-operative liver volumes of two measurements [IQQA(R)-liver semi-automated (Vs) and manual volume (Vm) measurements] in portal vein phase were compared with intra-operative measurement (Vio) by means of water displacement. Results Correlation analysis and Bland-Altman tests were used for statistical analysis.Results Pre-operative measurements of grafts resulted in a mean Vs, Vm, Vio of (818. 60 ± 161.43)cm3 , (880. 16 ± 169. 92) cm3 and (669. 84 ± 141.37) cm3 respectively. All corresponding pre-and intra-operative data were correlated significantly with each other. There was a good correlation between Vs and Vio(r= 0. 778, P<0. 05), so did Vm and Vio(r= 0. 746, P<0. 05). The equations of linear regression were Vio = Vs × 0. 681 + 112. 26, and Vio = Vm × 0. 620 + 123. 81 respectively. Exact 95 % CIs and the extent of concordance were 121.57-175. 95 cm3, -354. 135-56. 62 cm3 for semiautomated measurements, and 180. 09-240. 56 cm3 , - 438. 66-18. 01 cm3 for manual measurements,respectively. Conclusion Semi-automated method for the volumetric measurements of the right liver lobes in LDLT is more accurate than the manual method.