中华放射医学与防护杂志
中華放射醫學與防護雜誌
중화방사의학여방호잡지
Chinese Journal of Radiological Medicine and Protection
2011年
1期
87-90
,共4页
孔令海%孙晶星%姜恩海%焦玲%张文艺%张良安
孔令海%孫晶星%薑恩海%焦玲%張文藝%張良安
공령해%손정성%강은해%초령%장문예%장량안
心血管病%介入放射学%患者%辐射剂量
心血管病%介入放射學%患者%輻射劑量
심혈관병%개입방사학%환자%복사제량
Cardiovascular disease%Interventional radiology%Patients%Radiation dose
目的 对心血管介入手术中患者所受辐射剂量及与辐射剂量相关的指标进行采集和分析,为改善患者的辐射防护提供依据.方法 对在省属三级甲等医院进行的26例完整的心血管介入手术的患者进行临床数据采集,按手术类别分成冠状动脉血管造影术(CA)及行冠状动脉血管造影术(CA)后继续行经皮穿刺腔内冠状动脉成形术(PTCA)两组,采用TLD个人剂量计照射野矩阵测量法,检测患者荧光照射时间、入射皮肤剂量(ESD)、最高皮肤剂量(PSD)、剂量-面积乘积(DAP)等指标,用TLD测量在模拟心血管手术条件下体模器官剂量.结果 荧光透视时间为(17.7±15.6)min,范围为0.80~42.4 min;ESD范围为(159±138)mGy,4.40~459 mGy;PSD范围为(769±705)mGy,22.6~2.43×103mGy.CA+PTCA组的荧光照射时间、ESD、PSD均大于CA组,差异有统计学意义.最大皮肤受照剂量与透视时间有较好的相关性(r=0.84,P<0.01).结论 心血管病放射性介入操作时,可通过透视时间来估算最大皮肤受照剂量.
目的 對心血管介入手術中患者所受輻射劑量及與輻射劑量相關的指標進行採集和分析,為改善患者的輻射防護提供依據.方法 對在省屬三級甲等醫院進行的26例完整的心血管介入手術的患者進行臨床數據採集,按手術類彆分成冠狀動脈血管造影術(CA)及行冠狀動脈血管造影術(CA)後繼續行經皮穿刺腔內冠狀動脈成形術(PTCA)兩組,採用TLD箇人劑量計照射野矩陣測量法,檢測患者熒光照射時間、入射皮膚劑量(ESD)、最高皮膚劑量(PSD)、劑量-麵積乘積(DAP)等指標,用TLD測量在模擬心血管手術條件下體模器官劑量.結果 熒光透視時間為(17.7±15.6)min,範圍為0.80~42.4 min;ESD範圍為(159±138)mGy,4.40~459 mGy;PSD範圍為(769±705)mGy,22.6~2.43×103mGy.CA+PTCA組的熒光照射時間、ESD、PSD均大于CA組,差異有統計學意義.最大皮膚受照劑量與透視時間有較好的相關性(r=0.84,P<0.01).結論 心血管病放射性介入操作時,可通過透視時間來估算最大皮膚受照劑量.
목적 대심혈관개입수술중환자소수복사제량급여복사제량상관적지표진행채집화분석,위개선환자적복사방호제공의거.방법 대재성속삼급갑등의원진행적26례완정적심혈관개입수술적환자진행림상수거채집,안수술유별분성관상동맥혈관조영술(CA)급행관상동맥혈관조영술(CA)후계속행경피천자강내관상동맥성형술(PTCA)량조,채용TLD개인제량계조사야구진측량법,검측환자형광조사시간、입사피부제량(ESD)、최고피부제량(PSD)、제량-면적승적(DAP)등지표,용TLD측량재모의심혈관수술조건하체모기관제량.결과 형광투시시간위(17.7±15.6)min,범위위0.80~42.4 min;ESD범위위(159±138)mGy,4.40~459 mGy;PSD범위위(769±705)mGy,22.6~2.43×103mGy.CA+PTCA조적형광조사시간、ESD、PSD균대우CA조,차이유통계학의의.최대피부수조제량여투시시간유교호적상관성(r=0.84,P<0.01).결론 심혈관병방사성개입조작시,가통과투시시간래고산최대피부수조제량.
Objective To collect and analyze the radiation dose to patients in cardiovascular interventional procedures and the radiation dose-related indicators,in order to provide a basis for improving radiation protection of patients.MethodsThe clinical data of 26 cases of complete cardiovascular interventional procedures was collected in the municipal Grade A Class Three hospitals,including coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA),and the patient-received radiation doses and other related factors was studied.TLD personal dosimeter radiation field matrix method was used to measure fluorescence time,the entrance skin dose (ESD),the peak skin dose (PSD),dosearea product (DAP) and other indicators.TLD was used to measure the organ dose of the phantom under the cardiovascular interventional procedure condition.ResultsThe fluoroscopy time was (17.7 ±15.6) min during the range of 0.80-42.4 min.The average entrance skin dose (ESD) was (159 ± 138)mGy during the range of 4.40-459 mGy.The peak skin dose (PSD) was (769 ± 705) mGy during the range of 22.6 - 2.43 × 103mGy.The fluorescence time,entrance skin dose (ESD) ,peak skin dose (PSD) of the group CA + PTCA are greater than the group CA and the difference has statistical significan.The peak skin dose and the fluoroscopy time have good linear correlation (r = 0.84,P < 0.01 ).Conclusion The peak skin dose the patient received in cardiovascular interventional radiological operation can be estimated through the fluoroscopy time.