清华大学学报(英文版)
清華大學學報(英文版)
청화대학학보(영문판)
TSINGHUA SCIENCE AND TECHNOLOGY
2001年
1期
89-92
,共4页
The 5MW nuclear heating reactor is an integral naturalcirculation reactor. The rupture of the coolant penetrating tube is a typical accident causing coolant loss. When the water level drops down to the upper edge of the inlet of the heat exchanger, the natural circulation stops. This influences the core cooling and the stability of the main loop. A series of tests showed that there is a stable drop of pressure, and the heated element temperature is not too high to cause burnout. But the backward flow or flow oscillation in the primary coolant circuit occurs when the flow breaks completely in the end. The whole flow process is described and the mechanism is discussed.