国际呼吸杂志
國際呼吸雜誌
국제호흡잡지
INTERNATIONAL JOURNAL OF RESPIRATION
2012年
19期
1466-1470
,共5页
杨猛%陶一江%陈建荣%朱杰%姚苏梅
楊猛%陶一江%陳建榮%硃傑%姚囌梅
양맹%도일강%진건영%주걸%요소매
阻塞性睡眠呼吸暂低通气综合征%持续气道正压通气治疗%瘦素
阻塞性睡眠呼吸暫低通氣綜閤徵%持續氣道正壓通氣治療%瘦素
조새성수면호흡잠저통기종합정%지속기도정압통기치료%수소
Obstructive sleep apnea-hypopnea syndrome%Continuous positive airway pressure%Leptin
目的 探讨自动调节持续气道正压通气(auto-CPAP)治疗对阻塞性睡眠呼吸暂停低通气综合征(OSAHS)患者呼出气冷凝液(EBC)和血清中瘦素水平的影响.方法 根据多导睡眠监测确诊的42例中重度OSAHS患者,随机分为治疗组22例和对照组20例,对治疗组进行三个月auto-CPAP治疗,对治疗组和对照组患者均采取常规治疗,分别测定治疗组及对照组三个月前后EBC和血清中的瘦素.结果 ①治疗组患者EBC和血清中瘦素治疗前[(5.67±1.07) μg/L、(40.20±5.40)μg/L]高于治疗后[(3.75±1.09)μg/L、(30.46±5.82)μg/L](P<0.01);②对照组患者EBC和血清中Lep治疗前为[(5.52±1.14) μg/L、(42.19±4.96) μg/L],治疗后为[(5.95±1.26) μg/L、(42.69±4.33)μg/L],治疗前后差异无统计学意义(P>0.05);③OSAHS患者EBC和血清中瘦素水平与呼吸暂停低通气指数呈正相关(r=0.787,P<0.01; r=0.775,P<0.01),与最低血氧饱和度、平均血氧饱和度呈负相关(r=-0.829,P<0.01;r=0.794,P<0.01)、(r=-0.890,P<0.01;r=-0.830,P<0.01).结论 OSAHS患者存在高瘦素血症,auto-CPAP治疗可以改善OSAHS患者的高瘦素血症.
目的 探討自動調節持續氣道正壓通氣(auto-CPAP)治療對阻塞性睡眠呼吸暫停低通氣綜閤徵(OSAHS)患者呼齣氣冷凝液(EBC)和血清中瘦素水平的影響.方法 根據多導睡眠鑑測確診的42例中重度OSAHS患者,隨機分為治療組22例和對照組20例,對治療組進行三箇月auto-CPAP治療,對治療組和對照組患者均採取常規治療,分彆測定治療組及對照組三箇月前後EBC和血清中的瘦素.結果 ①治療組患者EBC和血清中瘦素治療前[(5.67±1.07) μg/L、(40.20±5.40)μg/L]高于治療後[(3.75±1.09)μg/L、(30.46±5.82)μg/L](P<0.01);②對照組患者EBC和血清中Lep治療前為[(5.52±1.14) μg/L、(42.19±4.96) μg/L],治療後為[(5.95±1.26) μg/L、(42.69±4.33)μg/L],治療前後差異無統計學意義(P>0.05);③OSAHS患者EBC和血清中瘦素水平與呼吸暫停低通氣指數呈正相關(r=0.787,P<0.01; r=0.775,P<0.01),與最低血氧飽和度、平均血氧飽和度呈負相關(r=-0.829,P<0.01;r=0.794,P<0.01)、(r=-0.890,P<0.01;r=-0.830,P<0.01).結論 OSAHS患者存在高瘦素血癥,auto-CPAP治療可以改善OSAHS患者的高瘦素血癥.
목적 탐토자동조절지속기도정압통기(auto-CPAP)치료대조새성수면호흡잠정저통기종합정(OSAHS)환자호출기냉응액(EBC)화혈청중수소수평적영향.방법 근거다도수면감측학진적42례중중도OSAHS환자,수궤분위치료조22례화대조조20례,대치료조진행삼개월auto-CPAP치료,대치료조화대조조환자균채취상규치료,분별측정치료조급대조조삼개월전후EBC화혈청중적수소.결과 ①치료조환자EBC화혈청중수소치료전[(5.67±1.07) μg/L、(40.20±5.40)μg/L]고우치료후[(3.75±1.09)μg/L、(30.46±5.82)μg/L](P<0.01);②대조조환자EBC화혈청중Lep치료전위[(5.52±1.14) μg/L、(42.19±4.96) μg/L],치료후위[(5.95±1.26) μg/L、(42.69±4.33)μg/L],치료전후차이무통계학의의(P>0.05);③OSAHS환자EBC화혈청중수소수평여호흡잠정저통기지수정정상관(r=0.787,P<0.01; r=0.775,P<0.01),여최저혈양포화도、평균혈양포화도정부상관(r=-0.829,P<0.01;r=0.794,P<0.01)、(r=-0.890,P<0.01;r=-0.830,P<0.01).결론 OSAHS환자존재고수소혈증,auto-CPAP치료가이개선OSAHS환자적고수소혈증.
Objective To investigate the effect of auto-CPAP therapy on the concentrations of leptin in exhaled breath condensate and plasma in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS).Methods 42 patients with moderate-to-severe OSAHS diagnosed by polysomnograpgy monitoring were randomly allocated to the active group (n =22) or the control group (n =20) respectively.The active group received the treatment of three months' auto-CPAP and all of the subjects received general treatment.Leptin levels in EBC and plasma were measured by enzyme linked immunosorbent assay (ELISA) before and after 3 months.Results ①The concentrations of leptin in EBC and plasma in the active group before treatment [(5.67± 1.07) μg/L,(40.20 ± 5.40) μg/L] were higher than the after [(3.75 ± 1.09) μg/L,(30.46 ± 5.82) μg/L].②The concentrations of leptin in EBC and plasma in the control group before treatment were[(5.52 ±1.14) μg/L,(42.19±4.96) μg/L] and were [(5.95± 1.26) μg/L,(42.69 ± 4.33) μg/L] after the treatment.But there was no statistical difference tetween the before and after the treatment.③Leptin levels in plasma and EBC were positively related with apnea hypoventilation index(AHI),and were inversely related with the lowest blood oxygen saturatin (r =-0.829,P<0.01.r =0.794,P <0.01)and average blood oxygen saturation (r=-0.890,P<0.01.r =-0.830,P <0.01).Conclusions The hyperleptinemia in OSAHS patients and can be improved by auto-CPAP treatment.