采用国产近红外在线分析仪,结合漫反射光谱分析技术,对广西某糖厂的白砂糖质量进行了在线应用研究.讨论了影响建模的因素,并提出一些解决问题的方案.采用SupNIR-4000型长波近红外在线分析仪,直接对产品传送带上的白砂糖进行扫描获得光谱数据,运用偏最小二乘法对实验数据进行多元统计分析建立数学模型,并进行了预测.样品色值的预测值和实测值间的相关系数为0.885,标准校正偏差为4.300,色值预测偏差小于糖厂要求的±10;样品浊度预测值和实测值间的相关系数为0.909,标准校正偏差为2.308,浊度预测偏差小于糖厂要求的±4.结果显示,模型预测结果符合糖厂要求,表明在线近红外技术在白砂糖质量监控中具有较好的应用前景.
採用國產近紅外在線分析儀,結閤漫反射光譜分析技術,對廣西某糖廠的白砂糖質量進行瞭在線應用研究.討論瞭影響建模的因素,併提齣一些解決問題的方案.採用SupNIR-4000型長波近紅外在線分析儀,直接對產品傳送帶上的白砂糖進行掃描穫得光譜數據,運用偏最小二乘法對實驗數據進行多元統計分析建立數學模型,併進行瞭預測.樣品色值的預測值和實測值間的相關繫數為0.885,標準校正偏差為4.300,色值預測偏差小于糖廠要求的±10;樣品濁度預測值和實測值間的相關繫數為0.909,標準校正偏差為2.308,濁度預測偏差小于糖廠要求的±4.結果顯示,模型預測結果符閤糖廠要求,錶明在線近紅外技術在白砂糖質量鑑控中具有較好的應用前景.
채용국산근홍외재선분석의,결합만반사광보분석기술,대엄서모당엄적백사당질량진행료재선응용연구.토론료영향건모적인소,병제출일사해결문제적방안.채용SupNIR-4000형장파근홍외재선분석의,직접대산품전송대상적백사당진행소묘획득광보수거,운용편최소이승법대실험수거진행다원통계분석건립수학모형,병진행료예측.양품색치적예측치화실측치간적상관계수위0.885,표준교정편차위4.300,색치예측편차소우당엄요구적±10;양품탁도예측치화실측치간적상관계수위0.909,표준교정편차위2.308,탁도예측편차소우당엄요구적±4.결과현시,모형예측결과부합당엄요구,표명재선근홍외기술재백사당질량감공중구유교호적응용전경.
Real-time monitoring of the quality of granulated sugar produced in Guangxi sugar factory was carried out using a domestic on-line near-infrared analyzer(SupNIR-4000) combined with diffuse reflectance spectrometry.The spectral data were obtained by scanning the granulated sugar on the belt conveyer with NIR analyzer.The proposed calibration models for the chroma and turbidity of sugar were based on the multivariate statistical analysis of their experimental data by the partial least square method.The factors,e.g.the thickness and graininess of granulated sugar,the fixing height of the diffuse reflectance probe and the temperature of granulated sugar and environment that affected the performances of calibration models were discussed in detail.Some methods were suggested to solve the problems.The chroma and turbidity values of granulated sugar were predicted by the optimized models.The results showed that the correlation coefficients between the predicted and experimental values were 0.885 for chroma with a standard deviation of 4.300,and 0.909 for turbidity with a standard deviation of 2.914.Since the prediction errors required by the sugar factory are ±10 for chroma and ±4 for turbidity,the predicted results could meet the requirement of the factory.Thus the proposed method is feasible for the real-time monitoring of the quality of granulated sugar in sugar industry.