润滑油
潤滑油
윤활유
LUBRICATING OIL
2011年
5期
40-42
,共3页
胡斌%程型国%周圆%李剑群
鬍斌%程型國%週圓%李劍群
호빈%정형국%주원%리검군
加压差示扫描量热仪%聚脲脂%氧化稳定性%活化能
加壓差示掃描量熱儀%聚脲脂%氧化穩定性%活化能
가압차시소묘량열의%취뇨지%양화은정성%활화능
pressure differential scanning calorimetry%polyurea grease%oxidation stability%activation energy
采用加压差示扫描量热仪测定了聚脲脂的起始氧化温度和氧化诱导期,讨论了不同类型的抗氧剂对聚脲脂抗氧化性能的影响,通过阿雷尼乌斯经验式计算出聚脲脂的活化能,从化学动力学的角度评价了聚脲脂的氧化安定性。
採用加壓差示掃描量熱儀測定瞭聚脲脂的起始氧化溫度和氧化誘導期,討論瞭不同類型的抗氧劑對聚脲脂抗氧化性能的影響,通過阿雷尼烏斯經驗式計算齣聚脲脂的活化能,從化學動力學的角度評價瞭聚脲脂的氧化安定性。
채용가압차시소묘량열의측정료취뇨지적기시양화온도화양화유도기,토론료불동류형적항양제대취뇨지항양화성능적영향,통과아뢰니오사경험식계산출취뇨지적활화능,종화학동역학적각도평개료취뇨지적양화안정성。
The initiative oxidation temperature and oxidation induction time of polyurea grease were determined by pressure differential scanning calorimetry.The effects of different anti-oxidation agents on the properties of polyurea grease were discussed.The activation energy of polyurea grease was calculated by Arrhenius empirical formula,and the oxidation stability was evaluated from the view of chemical dynamics.