常规化学绝缘监督方法是通过气相色谱法等手段来预测变压器内的潜伏性故障,但该方法判断变压器固体绝缘老化不准确,为此,介绍了监测固体绝缘老化的重要化学监测手段——糠醛测试,阐明测试的重要意义和方法,并结合日常工作实际提出了如何把糠醛测量有机地利用到化学预试中来。
常規化學絕緣鑑督方法是通過氣相色譜法等手段來預測變壓器內的潛伏性故障,但該方法判斷變壓器固體絕緣老化不準確,為此,介紹瞭鑑測固體絕緣老化的重要化學鑑測手段——糠醛測試,闡明測試的重要意義和方法,併結閤日常工作實際提齣瞭如何把糠醛測量有機地利用到化學預試中來。
상규화학절연감독방법시통과기상색보법등수단래예측변압기내적잠복성고장,단해방법판단변압기고체절연노화불준학,위차,개소료감측고체절연노화적중요화학감측수단——강철측시,천명측시적중요의의화방법,병결합일상공작실제제출료여하파강철측량유궤지이용도화학예시중래。
At present, latent troubles of transformers can be forecasted bymeans of gas chromatography. It is not accurate, however, to judge if the solid insulating systems in the transformers have been aged. Based on the fact, this paper introduces an important method of solid insulation monitoring---furane-formaldehyde measurement. At the same time, the authors present how to organically apply the method to chemical prediction in daily work.