中华眼视光学与视觉科学杂志
中華眼視光學與視覺科學雜誌
중화안시광학여시각과학잡지
CHINESE JOURNAL OF OPTOMETRY OPHTHALMOLOGY AND VISUAL SCIENCE
2012年
8期
457-461
,共5页
赵泽林%陈蔚%李锦阳%马慧香%孙莉
趙澤林%陳蔚%李錦暘%馬慧香%孫莉
조택림%진위%리금양%마혜향%손리
角膜移植%深板层角膜移植%角膜内皮移植%角膜板层刀%供体角膜
角膜移植%深闆層角膜移植%角膜內皮移植%角膜闆層刀%供體角膜
각막이식%심판층각막이식%각막내피이식%각막판층도%공체각막
Corneal transplantation%Deep anterior lamellar keratoplasty%Endothelial keratoplasty%Microkeratome%Donor corneas
目的 评估应用自动角膜板层刀切割一个供体角膜用于深板层角膜移植和角膜内皮移植的临床疗效及安全性.方法 回顾性系列病例研究.应用自动角膜板层刀预先将新鲜供体角膜进行切割,将带部分基质的角膜内皮植片用于角膜内皮移植术,剩余前板层用于深板层角膜移植术.回顾性分析2010年3~8月期间在温州医学院附属眼视光医院行角膜内皮移植术的17例患者及分别来自同一供体角膜的行深板层角膜移植的17例患者.术后随访19~24个月,分别观察角膜内皮贴附情况及前板层角膜植片愈合情况.随访资料包括医学验光、前节光学相干断层扫描及角膜内皮细胞计数.手术前后视力比较采用配对t检验.结果 17例角膜内皮移植患者术后角膜内皮植片均贴附良好,术后视力较术前均有提高.除l例碱烧伤患者因晶状体混浊,无法验光外,其余术后平均散光为(1.69±0.60)D.17例角膜内皮移植患者平均角膜内皮细胞计数为(2128±244)个/mm2,平均角膜内皮植片厚度为( 152±46)μm.17例前板层角膜移植患者角膜植片均透明,术后最佳矫正视力较术前提高,平均散光为 (2.50±0.90)D;平均前板层角膜植片厚度为(343±39)μm.结论 利用角膜板层刀将一个供体角膜用于两位患者的方法在临床实际应用中切实可行.经长期随访,角膜植片未出现明显并发症.该方法可以更充分地利用供体角膜,缓解中国供体角膜匮乏现状,意义重大.
目的 評估應用自動角膜闆層刀切割一箇供體角膜用于深闆層角膜移植和角膜內皮移植的臨床療效及安全性.方法 迴顧性繫列病例研究.應用自動角膜闆層刀預先將新鮮供體角膜進行切割,將帶部分基質的角膜內皮植片用于角膜內皮移植術,剩餘前闆層用于深闆層角膜移植術.迴顧性分析2010年3~8月期間在溫州醫學院附屬眼視光醫院行角膜內皮移植術的17例患者及分彆來自同一供體角膜的行深闆層角膜移植的17例患者.術後隨訪19~24箇月,分彆觀察角膜內皮貼附情況及前闆層角膜植片愈閤情況.隨訪資料包括醫學驗光、前節光學相榦斷層掃描及角膜內皮細胞計數.手術前後視力比較採用配對t檢驗.結果 17例角膜內皮移植患者術後角膜內皮植片均貼附良好,術後視力較術前均有提高.除l例堿燒傷患者因晶狀體混濁,無法驗光外,其餘術後平均散光為(1.69±0.60)D.17例角膜內皮移植患者平均角膜內皮細胞計數為(2128±244)箇/mm2,平均角膜內皮植片厚度為( 152±46)μm.17例前闆層角膜移植患者角膜植片均透明,術後最佳矯正視力較術前提高,平均散光為 (2.50±0.90)D;平均前闆層角膜植片厚度為(343±39)μm.結論 利用角膜闆層刀將一箇供體角膜用于兩位患者的方法在臨床實際應用中切實可行.經長期隨訪,角膜植片未齣現明顯併髮癥.該方法可以更充分地利用供體角膜,緩解中國供體角膜匱乏現狀,意義重大.
목적 평고응용자동각막판층도절할일개공체각막용우심판층각막이식화각막내피이식적림상료효급안전성.방법 회고성계렬병례연구.응용자동각막판층도예선장신선공체각막진행절할,장대부분기질적각막내피식편용우각막내피이식술,잉여전판층용우심판층각막이식술.회고성분석2010년3~8월기간재온주의학원부속안시광의원행각막내피이식술적17례환자급분별래자동일공체각막적행심판층각막이식적17례환자.술후수방19~24개월,분별관찰각막내피첩부정황급전판층각막식편유합정황.수방자료포괄의학험광、전절광학상간단층소묘급각막내피세포계수.수술전후시력비교채용배대t검험.결과 17례각막내피이식환자술후각막내피식편균첩부량호,술후시력교술전균유제고.제l례감소상환자인정상체혼탁,무법험광외,기여술후평균산광위(1.69±0.60)D.17례각막내피이식환자평균각막내피세포계수위(2128±244)개/mm2,평균각막내피식편후도위( 152±46)μm.17례전판층각막이식환자각막식편균투명,술후최가교정시력교술전제고,평균산광위 (2.50±0.90)D;평균전판층각막식편후도위(343±39)μm.결론 이용각막판층도장일개공체각막용우량위환자적방법재림상실제응용중절실가행.경장기수방,각막식편미출현명현병발증.해방법가이경충분지이용공체각막,완해중국공체각막궤핍현상,의의중대.
Objective To evaluate the safety and the clinical effects of a single corneal tissue donor specimen split by microkeratome and used for deep anterior lamellar keratoplasty and endothelial keratoplasty.Methods It was a retrospective case series study.Fresh donor corneas were split by microkeratome (Amadeus Ⅱ,Switzerland).The endothelial graft with a small section of the stroma was used for endothelial keratoplasty (EK), and the anterior lamellar button was used for deep anterior lamellar keratoplasty (DALK).Clinical data of 17 consecutive patients who underwent EK from March 2010 to August 2010 and 17 patients who underwent DALK whose donor grafts were matches for the endothelial grafts were reviewed.The attachment of the endothelial grafts and postoperative restitution of the anterior lamellar buttons were evaluated during the 19-24 month follow-up period.Optometric examinations,optical coherence tomography for all patients,and an endothelial cell count for patients who underwent EK were performed.Pre- and postoperative visual acuity analyzed using paired t test.Results The endothelial grafts of the 17 patients who underwent EK had attached well and postoperative visual acuity was improved.The mean astigmatism of the patients was 1.69±0.60 D with the exception of one alkali-burn patient whose optometric data was not available because of corneal opacity.The mean density of endothelial cells for the 17 patients who underwent EK was 2128±244 cells/mm2 and the mean thickness of the endothelial grafts was 152±46 μm.Anterior lamellar buttons of the 17 patients Who underwent DALK were transparent and postoperative best corrected visual acuity improved as well.The mean astigmatism was 2.50±0.90 D and the mean thickness of the anterior lamellar buttons was 343±39 μm.Conclusion The method of splitting a single donor cornea by microkeratome for two recipients is feasible in clinical applications.There were no serious complications caused by donor grafts during the long-term follow-up period. This method,which could make full use of donor corneas and alleviate the current shortage of donor corneas is of great significance.