中华放射医学与防护杂志
中華放射醫學與防護雜誌
중화방사의학여방호잡지
Chinese Journal of Radiological Medicine and Protection
2009年
1期
58-60
,共3页
李建彬%王巾帼%卢洁%于金明%马志芳%孙涛%郭守芳
李建彬%王巾幗%盧潔%于金明%馬誌芳%孫濤%郭守芳
리건빈%왕건귁%로길%우금명%마지방%손도%곽수방
自主呼吸控制%乳房%调强放射疗法%靶区勾画%靶区位移
自主呼吸控製%乳房%調彊放射療法%靶區勾畫%靶區位移
자주호흡공제%유방%조강방사요법%파구구화%파구위이
Active breathing control%Breast%Intensity-modulated radiotherapy%Target delineation%Target displacement
目的 探讨自主呼吸控制(ABC)辅助适度深吸气呼吸控制(mDIBH)状态下勾画者和勾画时间对乳腺癌保乳术后全乳靶区的影响及放疗分次内和放疗分次间全乳靶区的位移.方法 20例保乳术后拟行全乳调强放疗患者,ABC辅助CT模拟定位获得3个呼吸状态的5套CT图像[自由呼吸(FB)1套、适度深吸气呼吸控制(mDIBH)2套、深呼气呼吸控制(DEBH)2套].放疗10~15次再获5套CT图像.5位放疗医师和同一放疗医师不同时间分别在初次定位获得的第1套mDIBH图像上勾画全乳靶区,比较勾画者和勾画时间对全乳靶区影响.分别标记初次定位2套mDIBH图像上术腔中全部银夹,比较全部银夹所构成几何体在分次内位移.分别勾画初次定位2套和重复定位第1套mDIBH图像上近乳腺靶区等中心平面的2条肋骨,通过比较所勾画肋骨感兴趣点(POI)空间位置位移,获得分次内和分次间胸廓扩张差异.结果 同一医师不同时间勾画4次分别所得全乳靶区体积间差异无统计学意义,5位医师分别勾画全乳靶区体积差异有统计学意义(F=19.681,P=0.000);同一mDIBH状态下,分次内全部银夹所构成几何体POI各方向位移差异无统计学意义,分次内肋骨POI各方向位移差异无统计学意义;同一mDIBH状态下,分次间肋骨POI各方向位移差异无统计学意义.结论 不同勾画者所勾画全乳靶区差异是明显的.ABC辅助mDIBH状态下分次内及分次间全乳靶区位移在各个方向上的差异不明显.
目的 探討自主呼吸控製(ABC)輔助適度深吸氣呼吸控製(mDIBH)狀態下勾畫者和勾畫時間對乳腺癌保乳術後全乳靶區的影響及放療分次內和放療分次間全乳靶區的位移.方法 20例保乳術後擬行全乳調彊放療患者,ABC輔助CT模擬定位穫得3箇呼吸狀態的5套CT圖像[自由呼吸(FB)1套、適度深吸氣呼吸控製(mDIBH)2套、深呼氣呼吸控製(DEBH)2套].放療10~15次再穫5套CT圖像.5位放療醫師和同一放療醫師不同時間分彆在初次定位穫得的第1套mDIBH圖像上勾畫全乳靶區,比較勾畫者和勾畫時間對全乳靶區影響.分彆標記初次定位2套mDIBH圖像上術腔中全部銀夾,比較全部銀夾所構成幾何體在分次內位移.分彆勾畫初次定位2套和重複定位第1套mDIBH圖像上近乳腺靶區等中心平麵的2條肋骨,通過比較所勾畫肋骨感興趣點(POI)空間位置位移,穫得分次內和分次間胸廓擴張差異.結果 同一醫師不同時間勾畫4次分彆所得全乳靶區體積間差異無統計學意義,5位醫師分彆勾畫全乳靶區體積差異有統計學意義(F=19.681,P=0.000);同一mDIBH狀態下,分次內全部銀夾所構成幾何體POI各方嚮位移差異無統計學意義,分次內肋骨POI各方嚮位移差異無統計學意義;同一mDIBH狀態下,分次間肋骨POI各方嚮位移差異無統計學意義.結論 不同勾畫者所勾畫全乳靶區差異是明顯的.ABC輔助mDIBH狀態下分次內及分次間全乳靶區位移在各箇方嚮上的差異不明顯.
목적 탐토자주호흡공제(ABC)보조괄도심흡기호흡공제(mDIBH)상태하구화자화구화시간대유선암보유술후전유파구적영향급방료분차내화방료분차간전유파구적위이.방법 20례보유술후의행전유조강방료환자,ABC보조CT모의정위획득3개호흡상태적5투CT도상[자유호흡(FB)1투、괄도심흡기호흡공제(mDIBH)2투、심호기호흡공제(DEBH)2투].방료10~15차재획5투CT도상.5위방료의사화동일방료의사불동시간분별재초차정위획득적제1투mDIBH도상상구화전유파구,비교구화자화구화시간대전유파구영향.분별표기초차정위2투mDIBH도상상술강중전부은협,비교전부은협소구성궤하체재분차내위이.분별구화초차정위2투화중복정위제1투mDIBH도상상근유선파구등중심평면적2조륵골,통과비교소구화륵골감흥취점(POI)공간위치위이,획득분차내화분차간흉곽확장차이.결과 동일의사불동시간구화4차분별소득전유파구체적간차이무통계학의의,5위의사분별구화전유파구체적차이유통계학의의(F=19.681,P=0.000);동일mDIBH상태하,분차내전부은협소구성궤하체POI각방향위이차이무통계학의의,분차내륵골POI각방향위이차이무통계학의의;동일mDIBH상태하,분차간륵골POI각방향위이차이무통계학의의.결론 불동구화자소구화전유파구차이시명현적.ABC보조mDIBH상태하분차내급분차간전유파구위이재각개방향상적차이불명현.
Objective To explore the influence of different delineators and different delineating time on target determination of the whole breast and to explore intrafraction and interaction target displacements of the breast on moderate deep inspiration breathing hold (mDIBH) assisted by active breathing control (ABC) after breast conservative surgery. Methods Twenty patients received primary CT-simulation assisted by ABC to get five sets of CT image on the three breathing condition which included one set from free breath ( FB), two sets from mDIBH and two sets from deep expiration breathing control (DEBH). After radiotherapy with ten to fifteen fractions, the repeat CT-simulation was carried out to get the same five sets of CT image as the primary CT-simulation. The whole breast target were delineated at different time by the same delineator and delineated respectively by five delineators on the first set of CT images got with mDIBH from the primary CT-simulation,and to compare the influence of delineator and delineating time on the whole breast target. The total silver clips in the cavity were marked respectively on the two sets of CT images got with mDIBH from the primary CT-simulation, and to compare the intrafraction displacement of geometric body structured by the total of silver clips. The two ribs near the isocentric plane of the breast target were delineated respectively on two sets of the mDIBH CT image from the primary CT-simulation and on one set of the mDIBH CT image from the repeat CT-simulation, and comparing the movement of the point of interest (POI) of the ribs delineated to get the value of intrafraction and interfraction thoracic expansion. Results There was not statistically significant between the four volumes of whole breast targets delineated by the same delineator at different time, but with statistics significant between the volumes of whole breast target delineated by the different delineators(F = 19.681, P = 0.000). There was not statistically significant between the intrafraction displacements of the POI of the geometric body at each direction, and with no statistically significant between intrafraction displacements of the POI of the ribs delineated on the same mDIBH condition. There was not statistically significant between the interfraction displacements of the POI of the ribs delineated. Conclusions The influence of different delineators on the whole breast target is statistically significant. The difference of displacement of the breast target with the same mDIBH eondition assisted by ABC at the different direction is not statistically significant.