为充分发挥配电网模式化接线的优点并实现配电网故障处理与模式化接线的配合,提出对配电网采用模式化的故障处理方法,该方法利用变电站出线开关与分支线开关2级保护配合实现分支线或用户故障的就地切除。在此基础上通过对配电网各种典型接线模式特点的分析,分别建议了各种典型接线配电网在主干线或者电源点发生故障后的模式化故障处理步骤,包括:辐射状网、手拉手环状网、多分段多联络网、多供一备网、互为备用网、4×6接线网、双射网、对射网、双环网。指出只有结合模式化故障处理才能充分发挥模式化接线网架结构的优势。结合一些实例对所建议的模式化故障处理过程进行了详细说明。
為充分髮揮配電網模式化接線的優點併實現配電網故障處理與模式化接線的配閤,提齣對配電網採用模式化的故障處理方法,該方法利用變電站齣線開關與分支線開關2級保護配閤實現分支線或用戶故障的就地切除。在此基礎上通過對配電網各種典型接線模式特點的分析,分彆建議瞭各種典型接線配電網在主榦線或者電源點髮生故障後的模式化故障處理步驟,包括:輻射狀網、手拉手環狀網、多分段多聯絡網、多供一備網、互為備用網、4×6接線網、雙射網、對射網、雙環網。指齣隻有結閤模式化故障處理纔能充分髮揮模式化接線網架結構的優勢。結閤一些實例對所建議的模式化故障處理過程進行瞭詳細說明。
위충분발휘배전망모식화접선적우점병실현배전망고장처리여모식화접선적배합,제출대배전망채용모식화적고장처리방법,해방법이용변전참출선개관여분지선개관2급보호배합실현분지선혹용호고장적취지절제。재차기출상통과대배전망각충전형접선모식특점적분석,분별건의료각충전형접선배전망재주간선혹자전원점발생고장후적모식화고장처리보취,포괄:복사상망、수랍수배상망、다분단다련락망、다공일비망、호위비용망、4×6접선망、쌍사망、대사망、쌍배망。지출지유결합모식화고장처리재능충분발휘모식화접선망가결구적우세。결합일사실례대소건의적모식화고장처리과정진행료상세설명。
To give full play to advantages of modeled connection for distribution network and implement the coordination of fault treatment of distribution network with modeled connection, it is proposed to adopt modeled fault treatment method in distribution networks for fault isolation and restoration, namely using the protection coordination of circuit breakers for out-going line of substations with the circuit breakers for branch feeders to implement the in-situ tripping out of faulty feeder. On this basis, through the analysis on features of typical connection modes for distribution networks, the modeled fault treatment steps for distribution networks with various typical connections, such as radial distribution networks, looped distribution networks, multi-sectioned and multi-linked distribution networks and so on, are recommended when fault occurs in main power supply line or in power source point. It is pointed out that unless the modeled fault treatment is combined with, it is impossible to give full play to advantages of network structure with modeled connection. Based on case studies, the proposed modeled fault treatment procedures are described in detail.