介绍了某电厂锅炉水冷壁沉积物较多的基本情况。通过对沉积量和沉积物成分进行分析检测、对机组水汽品质进行查定和对锅炉燃烧工况等情况的分析认为:给水溶解氧的长期不合格导致省煤器等部位的氧腐蚀是造成锅炉水冷壁沉积物较多的主要原因。
介紹瞭某電廠鍋爐水冷壁沉積物較多的基本情況。通過對沉積量和沉積物成分進行分析檢測、對機組水汽品質進行查定和對鍋爐燃燒工況等情況的分析認為:給水溶解氧的長期不閤格導緻省煤器等部位的氧腐蝕是造成鍋爐水冷壁沉積物較多的主要原因。
개소료모전엄과로수랭벽침적물교다적기본정황。통과대침적량화침적물성분진행분석검측、대궤조수기품질진행사정화대과로연소공황등정황적분석인위:급수용해양적장기불합격도치성매기등부위적양부식시조성과로수랭벽침적물교다적주요원인。
The basic situation that the boiler water wall has more deposits in a power plant is introduced.Through detecting scale samples and measuring its quantity,checking the unit steam-water quality and analyzing the boiler burning conditions,it is concluded that long-term disqualification of water dissolved oxygen which leads to economizer oxygen corrosion is the main reason for that problem.