取水头%渗漏%钻孔%灌浆%压力%速凝剂%来宾火电B厂
取水頭%滲漏%鑽孔%灌漿%壓力%速凝劑%來賓火電B廠
취수두%삼루%찬공%관장%압력%속응제%래빈화전B엄
在来宾火电B厂水泵房取水头与隧道连接处的施工过程中,用严谨的科学态度对渗漏检查试验分析及采取有针对性的手段进行堵漏处理,具广泛性和实用价值,对其它相应的堵漏工程颇具有借鉴之意义。本工程一次性快速堵漏成功,得到了外国专家高度评价。
在來賓火電B廠水泵房取水頭與隧道連接處的施工過程中,用嚴謹的科學態度對滲漏檢查試驗分析及採取有針對性的手段進行堵漏處理,具廣汎性和實用價值,對其它相應的堵漏工程頗具有藉鑒之意義。本工程一次性快速堵漏成功,得到瞭外國專傢高度評價。
재래빈화전B엄수빙방취수두여수도련접처적시공과정중,용엄근적과학태도대삼루검사시험분석급채취유침대성적수단진행도루처리,구엄범성화실용개치,대기타상응적도루공정파구유차감지의의。본공정일차성쾌속도루성공,득도료외국전가고도평개。
During the construction of connection between water intake of water pump house and the tunnel, leakageinspection is carried out with rigorous scientism and corresponding measures are taken to treat the leakage in theconnection. As a practical leakage treatment, it can be learned and widely used by other similar projects. Foreignexperts speak highly of this quick and successful leakage treatment.