中国化学工程学报(英文版)
中國化學工程學報(英文版)
중국화학공정학보(영문판)
CHINESE JOURNAL OF CHEMICAL ENGINEERING
2004年
5期
633-638
,共6页
王军%苗君%刘芸%沈自求
王軍%苗君%劉蕓%瀋自求
왕군%묘군%류예%침자구
boiling heat transfer%vertical annulus tube%air introduction%interfacial vaporization heat sink
In this paper, boiling heat transfer in a vertical annulus with inner side heated with and without air introduction is experimentally studied. Results show that boiling heat transfer is significantly enhanced by the introduction of air. When air is introduced into the liquid with a temperature below boiling point, the enhancement of heat transfer is also detected. It is concluded from the study that the heat transfer enhanced by introduction of inert gas is due to the liquid vaporization at the gas-liquid interface near the wall, which removes a large amount of latent heat and lowers the interfacial temperature considerably. Thus the gas-liquid interface acts as a "heat sink"and the heat transfer is augmented significantly.