目的 评价DSA特殊功能在子宫肌瘤栓塞治疗中的价值.方法 46例子宫肌瘤栓塞中26例应用DSA特殊功能:3D-DSA、最佳工作体位、路图技术,20例采用常规DSA造影,对两种方法的对比剂用量、介入手术时间和透视时间进行比较和分析.结果 术中应用DSA特殊功能与常规DSA组比较,对比剂用量和透视时间明显减少(P<0.05),手术时间差异无统计学意义(P>0.05).结论 DSA特殊功能在子宫肌瘤栓塞中的应用能缩短手术时间,降低手术风险.可视化三维重建技术对介入手术操作具有重要指导意义.
目的 評價DSA特殊功能在子宮肌瘤栓塞治療中的價值.方法 46例子宮肌瘤栓塞中26例應用DSA特殊功能:3D-DSA、最佳工作體位、路圖技術,20例採用常規DSA造影,對兩種方法的對比劑用量、介入手術時間和透視時間進行比較和分析.結果 術中應用DSA特殊功能與常規DSA組比較,對比劑用量和透視時間明顯減少(P<0.05),手術時間差異無統計學意義(P>0.05).結論 DSA特殊功能在子宮肌瘤栓塞中的應用能縮短手術時間,降低手術風險.可視化三維重建技術對介入手術操作具有重要指導意義.
목적 평개DSA특수공능재자궁기류전새치료중적개치.방법 46례자궁기류전새중26례응용DSA특수공능:3D-DSA、최가공작체위、로도기술,20례채용상규DSA조영,대량충방법적대비제용량、개입수술시간화투시시간진행비교화분석.결과 술중응용DSA특수공능여상규DSA조비교,대비제용량화투시시간명현감소(P<0.05),수술시간차이무통계학의의(P>0.05).결론 DSA특수공능재자궁기류전새중적응용능축단수술시간,강저수술풍험.가시화삼유중건기술대개입수술조작구유중요지도의의.
Objective To evaluate the special functions of DSA in interventional embolization therapy for uterine fibroids. Methods The special functions of DSA, including 3D-DSA, the optimal working position and road-mapping technique, were utilized in performing interventional embolization therapy for uterine fibroids in twenty-six cases (experimental group). Routine DSA angiography was employed in twenty cases (control group). The volume of contrast media used, the time of completing the interventional procedure and the total fluoroscopic time in two groups were compared and the results were analyzed. Results The difference in the volume of contrast agent used and in the total fluoroscopic time between two groups was statistically significant (P < 0.05), although no significant difference in the time of completing interventional procedure existed between two groups (P > 0.05). Conclusion In treating uterine fibroids with interventional embolization, the use of the special functions of DSA can reduce the manipulation time and lower the operation risk. Moreover, the technique of visible 3D reconstruction image is of great significance in guiding the procedure.