中华超声影像学杂志
中華超聲影像學雜誌
중화초성영상학잡지
CHINESE JOURNAL OF ULTRASONOGRAPHY
2010年
9期
765-768
,共4页
张云姣%赵博文%潘美%杨园%杨倩%徐海珊%王蓓
張雲姣%趙博文%潘美%楊園%楊倩%徐海珊%王蓓
장운교%조박문%반미%양완%양천%서해산%왕배
超声心动描记术%胎儿%心脏强回声结构
超聲心動描記術%胎兒%心髒彊迴聲結構
초성심동묘기술%태인%심장강회성결구
Echocardiography%Fetus%Intracardiac hyperechogenic focus
目的 探讨超声心动图检测胎儿心脏强回声结构(intracardiac hyperechogenic focus,ICEF)及对ICEF胎儿心功能评价的临床意义.方法 采用胎儿超声心动图对1291例孕22~40周胎儿进行检测,对检出的ICEF胎儿测量心脏大小及室壁厚度,定量主动脉瓣口、肺动脉瓣口、房室瓣口血流速度,测量房室瓣环舒张早期、舒张晚期及收缩期运动的峰值速度(Em、Am、Sm);随机选择128例正常胎儿作为对照组并测量相关参数;比较单纯ICEF胎儿与正常胎儿间的心脏收缩及舒张功能参数.结果 共检出ICEF胎儿448例,检出率34.7%(448/1291),其中伴先天性心血管畸形24例(5.4%),轻度三尖瓣反流24例(5.4%),染色体异常1例(0.22%).399例单纯ICEF胎儿与正常胎儿之间比较,二维及M型超声心动图所测心脏大小及室壁厚度等参数差异均无统计学意义(P>0.05),单纯性ICEF胎儿与正常胎儿之间比较,主动脉瓣口、肺动脉瓣口、房室瓣口血流流速曲线及房室瓣环运动速度参数差异均无统计学意义(P>0.05).结论 单纯性的ICEF胎儿伴发染色体异常的几率较低,并不伴明显血流动力学改变.
目的 探討超聲心動圖檢測胎兒心髒彊迴聲結構(intracardiac hyperechogenic focus,ICEF)及對ICEF胎兒心功能評價的臨床意義.方法 採用胎兒超聲心動圖對1291例孕22~40週胎兒進行檢測,對檢齣的ICEF胎兒測量心髒大小及室壁厚度,定量主動脈瓣口、肺動脈瓣口、房室瓣口血流速度,測量房室瓣環舒張早期、舒張晚期及收縮期運動的峰值速度(Em、Am、Sm);隨機選擇128例正常胎兒作為對照組併測量相關參數;比較單純ICEF胎兒與正常胎兒間的心髒收縮及舒張功能參數.結果 共檢齣ICEF胎兒448例,檢齣率34.7%(448/1291),其中伴先天性心血管畸形24例(5.4%),輕度三尖瓣反流24例(5.4%),染色體異常1例(0.22%).399例單純ICEF胎兒與正常胎兒之間比較,二維及M型超聲心動圖所測心髒大小及室壁厚度等參數差異均無統計學意義(P>0.05),單純性ICEF胎兒與正常胎兒之間比較,主動脈瓣口、肺動脈瓣口、房室瓣口血流流速麯線及房室瓣環運動速度參數差異均無統計學意義(P>0.05).結論 單純性的ICEF胎兒伴髮染色體異常的幾率較低,併不伴明顯血流動力學改變.
목적 탐토초성심동도검측태인심장강회성결구(intracardiac hyperechogenic focus,ICEF)급대ICEF태인심공능평개적림상의의.방법 채용태인초성심동도대1291례잉22~40주태인진행검측,대검출적ICEF태인측량심장대소급실벽후도,정량주동맥판구、폐동맥판구、방실판구혈류속도,측량방실판배서장조기、서장만기급수축기운동적봉치속도(Em、Am、Sm);수궤선택128례정상태인작위대조조병측량상관삼수;비교단순ICEF태인여정상태인간적심장수축급서장공능삼수.결과 공검출ICEF태인448례,검출솔34.7%(448/1291),기중반선천성심혈관기형24례(5.4%),경도삼첨판반류24례(5.4%),염색체이상1례(0.22%).399례단순ICEF태인여정상태인지간비교,이유급M형초성심동도소측심장대소급실벽후도등삼수차이균무통계학의의(P>0.05),단순성ICEF태인여정상태인지간비교,주동맥판구、폐동맥판구、방실판구혈류류속곡선급방실판배운동속도삼수차이균무통계학의의(P>0.05).결론 단순성적ICEF태인반발염색체이상적궤솔교저,병불반명현혈류동역학개변.
Objective To evaluate the clinical significance and cardiac function of fetuses with intracardiac hyperechogenic focus(ICEF) by fetal echocardiography. Methods Fetal echocardiograms were performed on 1291 fetuses for evaluation of fetal heart structures and rhythms. Echocardiographic characteristics of ICEF were investigated. Fetal systolic and diastolic functions of 399 fetuses with an isolated ICEF were compared with 128 normal fetuses using conventional two-dimensional, M-mode, pulsed Doppler echocardiography and myocardial Doppler tissue imaging(DTI). Results The prevalence of ICEF was 34. 7% (448/1291). Twenty-four(5.4%) cases were found with cardiovascular malformations. There was 1 (0.22%) case of ICEF fetus associated with chromosomal abnormality (trisomy 21 ). Comprehensive fetal echocardiographic data analysis showed no significant differences in heart dimensions, global cardiac functions,and myocardial performances in the two groups( P >0.05). Conclusions An isolated ICEF in the fetal heart is not associated with increased risk for chromosome abnormalities. Fetuses with ICEF do not indicate impaired left ventricular systolic or diastolic function, therefore having no hemodynamic significance.