以人肝癌细胞株HepG2为研究对象,以压电细胞芯片技术为研究手段,进行了紫杉醇药效的压电细胞芯片实时检测;同时与传统的MTT比色方法进行对比,得到了较为一致的实验结果,即药物浓度与细胞的生长抑制率呈正相关.与传统方法相比,压电细胞芯片技术更省时,更动态,是一种体外筛选药物的好方法.
以人肝癌細胞株HepG2為研究對象,以壓電細胞芯片技術為研究手段,進行瞭紫杉醇藥效的壓電細胞芯片實時檢測;同時與傳統的MTT比色方法進行對比,得到瞭較為一緻的實驗結果,即藥物濃度與細胞的生長抑製率呈正相關.與傳統方法相比,壓電細胞芯片技術更省時,更動態,是一種體外篩選藥物的好方法.
이인간암세포주HepG2위연구대상,이압전세포심편기술위연구수단,진행료자삼순약효적압전세포심편실시검측;동시여전통적MTT비색방법진행대비,득도료교위일치적실험결과,즉약물농도여세포적생장억제솔정정상관.여전통방법상비,압전세포심편기술경성시,경동태,시일충체외사선약물적호방법.
As a new method of screening drugs, Petroelectric-cell-chip was used to monitor effects of Paclitaxel on human hepatoma cells HepG2 adhesions. Meanwhile the traditional method-MTT was also carried to confirm the effects of anti-cancer drug on HepG2 cells, or the concentration was proportional to the growth inhibition ratio of the cells. Results showed petroelectric-cell-chip was more effective than other methods to screen anti-cancer drugs, moreover in real-time.