介绍了HLS(合肥光源)储存环注入系统建造与调试情况.重点讨论了各种公差、公差判断及抑制措施,经过改进与及仔细调整,得到了平均累积速率2-6mA/s的日常运行水平,最高累积流强400mA,该系统已经稳定使用近两年,在光源的运行中起到了重要作用.
介紹瞭HLS(閤肥光源)儲存環註入繫統建造與調試情況.重點討論瞭各種公差、公差判斷及抑製措施,經過改進與及仔細調整,得到瞭平均纍積速率2-6mA/s的日常運行水平,最高纍積流彊400mA,該繫統已經穩定使用近兩年,在光源的運行中起到瞭重要作用.
개소료HLS(합비광원)저존배주입계통건조여조시정황.중점토론료각충공차、공차판단급억제조시,경과개진여급자세조정,득도료평균루적속솔2-6mA/s적일상운행수평,최고루적류강400mA,해계통이경은정사용근량년,재광원적운행중기도료중요작용.
This paper describes the construction and the commissioning of the new injection bump system of HLS ring. An emphasis of the discussion is put on various errors of the system and the method of evaluation and reduction. After some improvements and fine adjustment, an average injection rate of 2-6mA/s was obtained in the daily operation and a maximum accumulated current of 400mA achieved. The injection system has run for almost two years and played an important role in the operation of the light source.