目的 评价在亚洲人群乳腺癌筛查中使用钼靶X线诊断乳腺癌的准确性.方法 2002年3月至2007年9月,收集8718名常规体检的成都市社区女性的乳腺钼靶X线检查资料,分别以病理组织学结果和随访结果为最终诊断的金标准,计算钼靶X线诊断乳腺癌的敏感度和特异度.检索国内外有关钼靶X线用于亚洲女性一般人群乳腺癌筛查的研究,连同上述队列资料一起纳入Meta分析,计算合并敏感度、特异度及诊断比值比(DOR),并绘制综合受试者工作特征曲线(SROC),评价其诊断效能.结果 基于成都社区的随访研究显示,钼靶x线诊断乳腺癌的敏感度为0.889(95%CI为0.741~0.970),特异度为0.991(95%CI为0.987~0.993).Meta分析共纳入合格研究7个,共计研究对象223 619人.纳入的研究具有异质性,按照随机效应模型(REM)计算出的合并敏感度为0.845(95%CI为0.821~0.870),特异度为0.930(95%CI为0.929~0.931),DOR为117.271(95%CI为65.060~211.412),SROC下面积为0.9144.结论 钼靶X线在亚洲女性乳腺癌筛查中有较高的准确性.
目的 評價在亞洲人群乳腺癌篩查中使用鉬靶X線診斷乳腺癌的準確性.方法 2002年3月至2007年9月,收集8718名常規體檢的成都市社區女性的乳腺鉬靶X線檢查資料,分彆以病理組織學結果和隨訪結果為最終診斷的金標準,計算鉬靶X線診斷乳腺癌的敏感度和特異度.檢索國內外有關鉬靶X線用于亞洲女性一般人群乳腺癌篩查的研究,連同上述隊列資料一起納入Meta分析,計算閤併敏感度、特異度及診斷比值比(DOR),併繪製綜閤受試者工作特徵麯線(SROC),評價其診斷效能.結果 基于成都社區的隨訪研究顯示,鉬靶x線診斷乳腺癌的敏感度為0.889(95%CI為0.741~0.970),特異度為0.991(95%CI為0.987~0.993).Meta分析共納入閤格研究7箇,共計研究對象223 619人.納入的研究具有異質性,按照隨機效應模型(REM)計算齣的閤併敏感度為0.845(95%CI為0.821~0.870),特異度為0.930(95%CI為0.929~0.931),DOR為117.271(95%CI為65.060~211.412),SROC下麵積為0.9144.結論 鉬靶X線在亞洲女性乳腺癌篩查中有較高的準確性.
목적 평개재아주인군유선암사사중사용목파X선진단유선암적준학성.방법 2002년3월지2007년9월,수집8718명상규체검적성도시사구녀성적유선목파X선검사자료,분별이병리조직학결과화수방결과위최종진단적금표준,계산목파X선진단유선암적민감도화특이도.검색국내외유관목파X선용우아주녀성일반인군유선암사사적연구,련동상술대렬자료일기납입Meta분석,계산합병민감도、특이도급진단비치비(DOR),병회제종합수시자공작특정곡선(SROC),평개기진단효능.결과 기우성도사구적수방연구현시,목파x선진단유선암적민감도위0.889(95%CI위0.741~0.970),특이도위0.991(95%CI위0.987~0.993).Meta분석공납입합격연구7개,공계연구대상223 619인.납입적연구구유이질성,안조수궤효응모형(REM)계산출적합병민감도위0.845(95%CI위0.821~0.870),특이도위0.930(95%CI위0.929~0.931),DOR위117.271(95%CI위65.060~211.412),SROC하면적위0.9144.결론 목파X선재아주녀성유선암사사중유교고적준학성.
Objective To evaluate the accuracy of mammography in breast cancer screening in Asian women.Methods 8718 community women in Chengdu were examined by mammography during the routine physical examination from Mar.2002 to Sep.2007.Pathological diagnosis and following up results were used as the gold standards for X-my-positive and-negative findings.The sensitivity,specificity and diagnosis odds ratio were calculated as accuracy indexes.Large scale follow-up studies of breast cancer screening in community in Asian women were collected to evaluate the pooled accuracy of mammography.Diagnosis meta-analysis was conducted with Meta-Disc software to estimate the pooled sensitivity.specifieity and DOR,and draw the summary receiver operating characteristic(SROC).Results The data of seven studies were included with a total of 223 619 women received mammography for screening breast cancer.The sensitivity(95%CI) and specificity(95%CI)of mammography of community-based follow-up study in Chengdu were 0.889(0.741-0.970)and 0.991(0.987-0.993),respectively.Referring to meta.analysis, random effects models were adopted due to existed heterogeneity among studies.The pooled sensitivity,specificity,DOR with their 95% confidence intervals were 0.845(0.821-0.870),0.930(0.929-0.931)and 117.271(65.060-211.412),respectively.The Area Under the Curve(AUC)of SROC was 0.9144.Conclusion Due to its high accuracy,mammography deserves to be recommend in breast cancer screening in Asian women.