中国实用眼科杂志
中國實用眼科雜誌
중국실용안과잡지
CHINESE JOURNAL OF PRACTICAL OPHTHALMOLOGY
2012年
6期
694-697
,共4页
肖卉%范忠义%孟白兰%张淑琦%魏晓雯%李昂%孙美玲
肖卉%範忠義%孟白蘭%張淑琦%魏曉雯%李昂%孫美玲
초훼%범충의%맹백란%장숙기%위효문%리앙%손미령
近视%角膜滞后量%角膜阻力因子%中央角膜厚度%眼反应分析仪
近視%角膜滯後量%角膜阻力因子%中央角膜厚度%眼反應分析儀
근시%각막체후량%각막조력인자%중앙각막후도%안반응분석의
Myopia%Corneal hysteresis%Corneal resistance factor%Central corneal thickness%Ocular response analyzer
目的 研究眼反应分析仪(ORA)测量的角膜生物力学指标角膜滞后量(corneal hysteresis,CH)和角膜阻力因子(corneal resistance factor,CRF)在近视人群中的测量值以及在不同程度近视患者之间的差异.方法 对357例692只眼近视患者,分为轻度近视组(≤-3.00 D)、中度近视组(-3.00~ -6.00 D)、高度近视组(-6.00 D~-10.00 D),超高度近视组(≥-10.00 D),利用眼反应分析仪测量各组CH、CRF值及超声角膜测厚仪测量中央角膜厚度(central corneal thickness,CCT),并对测量结果进行统计学分析.结果 全部患者平均CH值为(10.51±1.54) mm Hg(1 kPa=7.5 mm Hg),CRF值为(10.61±1.63)mm Hg,平均CCT值(533.24±32.14)μm.轻、中度近视组CH值与高、超高 度近视组比较差异具有统计学意义(P<0.05),轻、中度近视组CRF值超高度近视组比较差异具有统计学意义(P<0.05).各组CCT值对比差异无统计学意义.结论 随着近视程度的加深,角膜生物力学特性发生改变,角膜粘滞性及眼球硬度降低.
目的 研究眼反應分析儀(ORA)測量的角膜生物力學指標角膜滯後量(corneal hysteresis,CH)和角膜阻力因子(corneal resistance factor,CRF)在近視人群中的測量值以及在不同程度近視患者之間的差異.方法 對357例692隻眼近視患者,分為輕度近視組(≤-3.00 D)、中度近視組(-3.00~ -6.00 D)、高度近視組(-6.00 D~-10.00 D),超高度近視組(≥-10.00 D),利用眼反應分析儀測量各組CH、CRF值及超聲角膜測厚儀測量中央角膜厚度(central corneal thickness,CCT),併對測量結果進行統計學分析.結果 全部患者平均CH值為(10.51±1.54) mm Hg(1 kPa=7.5 mm Hg),CRF值為(10.61±1.63)mm Hg,平均CCT值(533.24±32.14)μm.輕、中度近視組CH值與高、超高 度近視組比較差異具有統計學意義(P<0.05),輕、中度近視組CRF值超高度近視組比較差異具有統計學意義(P<0.05).各組CCT值對比差異無統計學意義.結論 隨著近視程度的加深,角膜生物力學特性髮生改變,角膜粘滯性及眼毬硬度降低.
목적 연구안반응분석의(ORA)측량적각막생물역학지표각막체후량(corneal hysteresis,CH)화각막조력인자(corneal resistance factor,CRF)재근시인군중적측량치이급재불동정도근시환자지간적차이.방법 대357례692지안근시환자,분위경도근시조(≤-3.00 D)、중도근시조(-3.00~ -6.00 D)、고도근시조(-6.00 D~-10.00 D),초고도근시조(≥-10.00 D),이용안반응분석의측량각조CH、CRF치급초성각막측후의측량중앙각막후도(central corneal thickness,CCT),병대측량결과진행통계학분석.결과 전부환자평균CH치위(10.51±1.54) mm Hg(1 kPa=7.5 mm Hg),CRF치위(10.61±1.63)mm Hg,평균CCT치(533.24±32.14)μm.경、중도근시조CH치여고、초고 도근시조비교차이구유통계학의의(P<0.05),경、중도근시조CRF치초고도근시조비교차이구유통계학의의(P<0.05).각조CCT치대비차이무통계학의의.결론 수착근시정도적가심,각막생물역학특성발생개변,각막점체성급안구경도강저.
Objective To investigate the differences of the corneal hysteresis (CH) and the comeal resistance factor (CRF) among various degrees myopia patients. Methods A total of 357 myopia patients (692 eyes) were divided into mild myopia group (≤ -3.00 D),moderate myopia group (-3.00D to-6.00D), high myopia group (-6.00D to-10.00D) and heavy high myopia group (≥ -10.00D).CH and CRF was measured by ocular response analyzer (ORA) and central corneal thickness (CCT) was detected on the same time.The relationships among these group's parameters were analyzed statistically. Results The average CH value was (10.51±1.54) mmHg in all myopia groups,the average CRF value was (10.61±1.63) mmHg,the average CCT value was (533.24±32.14)μm.Significant differences were between mild myopia,moderate myopia groups and high,heavy high group (P < 0.05) for CH value.In terms of the CRF value,there was significant difference among mild myopia,moderate myopia and heavy high myopia.There was no significant difference in CCT value among the groups. Conclusions With the increase of the sphere equivalence,CCT value has no obvious change,but CH and CRF value are decreased.