化学研究与应用
化學研究與應用
화학연구여응용
CHEMICAL RESEARCH AND APPLICATION
2010年
4期
472-474
,共3页
杜凌云%李立华%姚型军%王术皓
杜凌雲%李立華%姚型軍%王術皓
두릉운%리립화%요형군%왕술호
N-氯代丁二酰亚胺%鲁米诺%化学发光%苯酚
N-氯代丁二酰亞胺%魯米諾%化學髮光%苯酚
N-록대정이선아알%로미낙%화학발광%분분
N-chlorosuccinimide%Luminol%Chemiluminescence%Phenol
A new flow injection chemiluminesenet method was presented for the determination of phenol based on the inhibition effect of trace phenol on the chemiluminescence reaction between luminol and N-chlorosuccinimide system.The linear range for the determination of phenol is 1.5×10~(-5)~3.5×10~(-4)mg/mL,the detection limit is 2.36×10~(-6)mg/mL.This method has been used for the determination of phenol in water samples with satisfactory results.The mechanism of the inhibitory reaction was also discussed.