赵静%杜联芳%邢晋放%李凡%顾继英%白敏
趙靜%杜聯芳%邢晉放%李凡%顧繼英%白敏
조정%두련방%형진방%리범%고계영%백민
超声检查%肾移植%慢性移植肾肾病%声触诊组织定量
超聲檢查%腎移植%慢性移植腎腎病%聲觸診組織定量
초성검사%신이식%만성이식신신병%성촉진조직정량
Ultrasonography%Kidney transplantation%Chronic allograft nephropathy%Virtual touch tissue quantification
目的 探讨声触诊组织定量(virtual touch tissue quantification,VTQ)技术在慢性移植肾肾病(chronic allograft nephropathy,CAN)检测中的应用价值.方法 选择48例移植肾功能正常患者及50例CAN患者,分别对移植肾行彩色多普勒及VTQ检查,并对检查结果进行对比分析.结果 CAN组和移植肾功能正常组之间VTQ值差异有统计学意义(P<0,05).用ROC曲线分析阈值,当VTQ值≥2.51 m/s时,诊断CAN的敏感性、特异性、阳性预测值、阴性预测值分别为76.0%、52.1%、60.3%、65.7%,诊断准确度为62.2%.结论 VTQ技术可定量反映移植肾皮质的弹性变化,测值稳定,可重复性强,能够用于监测移植肾功能变化及早期诊断CAN.
目的 探討聲觸診組織定量(virtual touch tissue quantification,VTQ)技術在慢性移植腎腎病(chronic allograft nephropathy,CAN)檢測中的應用價值.方法 選擇48例移植腎功能正常患者及50例CAN患者,分彆對移植腎行綵色多普勒及VTQ檢查,併對檢查結果進行對比分析.結果 CAN組和移植腎功能正常組之間VTQ值差異有統計學意義(P<0,05).用ROC麯線分析閾值,噹VTQ值≥2.51 m/s時,診斷CAN的敏感性、特異性、暘性預測值、陰性預測值分彆為76.0%、52.1%、60.3%、65.7%,診斷準確度為62.2%.結論 VTQ技術可定量反映移植腎皮質的彈性變化,測值穩定,可重複性彊,能夠用于鑑測移植腎功能變化及早期診斷CAN.
목적 탐토성촉진조직정량(virtual touch tissue quantification,VTQ)기술재만성이식신신병(chronic allograft nephropathy,CAN)검측중적응용개치.방법 선택48례이식신공능정상환자급50례CAN환자,분별대이식신행채색다보륵급VTQ검사,병대검사결과진행대비분석.결과 CAN조화이식신공능정상조지간VTQ치차이유통계학의의(P<0,05).용ROC곡선분석역치,당VTQ치≥2.51 m/s시,진단CAN적민감성、특이성、양성예측치、음성예측치분별위76.0%、52.1%、60.3%、65.7%,진단준학도위62.2%.결론 VTQ기술가정량반영이식신피질적탄성변화,측치은정,가중복성강,능구용우감측이식신공능변화급조기진단CAN.
Objective To investigate the feasibility of virtual touch tissue quantification(VTQ) for the assessment of chronic allograft nephropathy(CAN).Methods 48 patients with normal renal function and 50 patients with CAN were checked by color Doppler and VTQ technique.All the results were compared between two groups.Results Mean VTQ-values were significantly different between the two groups( P < 0.05).ROC curve displayed that VTQ value of 2.51 m/s could be used to diagnose CAN,the sensitivity,specificity,positive predictive value and negative predictive value were 76.0%,52.1%,60.3% and 65.7%,respectively.The diagnostic efficiency was 62.2%.Conclusions Parenchymal stiffness measured by VTQ is stable and repeatable,which can be used to diagnose patients with CAN and to monitor renal function.