湖南工业大学学报
湖南工業大學學報
호남공업대학학보
JOURNAL OF HUNAN UNIVERSITY OF TECHNOLOGY
2011年
4期
86-90
,共5页
洁净厂房%气流组织%数值模拟%CFD
潔淨廠房%氣流組織%數值模擬%CFD
길정엄방%기류조직%수치모의%CFD
cleaning workshop%air flow%numerical simulation%CFD
以CFD为辅助工具,对印制线路板工序的关键车间涂覆房IS07级洁净室进行气流组织模拟设计,并用Airpak软件对其进行求解,对模拟数据与实测数据进行比较。结果表明,由于人流和物流的影响,模拟数据虽有一定偏差,但基本准确。数值模拟有助于设计师选择合适的气流组织和温湿度场。
以CFD為輔助工具,對印製線路闆工序的關鍵車間塗覆房IS07級潔淨室進行氣流組織模擬設計,併用Airpak軟件對其進行求解,對模擬數據與實測數據進行比較。結果錶明,由于人流和物流的影響,模擬數據雖有一定偏差,但基本準確。數值模擬有助于設計師選擇閤適的氣流組織和溫濕度場。
이CFD위보조공구,대인제선로판공서적관건차간도복방IS07급길정실진행기류조직모의설계,병용Airpak연건대기진행구해,대모의수거여실측수거진행비교。결과표명,유우인류화물류적영향,모의수거수유일정편차,단기본준학。수치모의유조우설계사선택합괄적기류조직화온습도장。
With CFD as auxiliary tool, conducts an analog design for ISO7 clean airflow in the key coating workshop of PCB process, uses the software of Airpak for the solution and compares the simulated data with the measured data. The results show that due to the impacts of people and logistics flows, the simulation data deviates from the measured, but it is basically accurate. Numerical simulation helps designers to choose the right air flow and temperature-humidity field.