原有冷却器在运行中存在出力不足和工质泄漏两个方面的问题,经分析研究,找出了存在问题的原
因,并提出了解决措施,研制开发了新型全逆流管壳式冷却器。图2表2参2
原有冷卻器在運行中存在齣力不足和工質洩漏兩箇方麵的問題,經分析研究,找齣瞭存在問題的原
因,併提齣瞭解決措施,研製開髮瞭新型全逆流管殼式冷卻器。圖2錶2參2
원유냉각기재운행중존재출력불족화공질설루량개방면적문제,경분석연구,조출료존재문제적원
인,병제출료해결조시,연제개발료신형전역류관각식냉각기。도2표2삼2
The existed cooler in Beilun Power Plant has two problems during operation: cooling power
inefficient and working medium leaking. The measure to solve those two problems has been found and
presented in this paper. And a new style of cooler--total counter carrent tube--casing cooler is
designed. Figs 2, tables 2 and refs2.