新型%电力机车%风道继电器
新型%電力機車%風道繼電器
신형%전력궤차%풍도계전기
new type%electric locomotive%air duct relay
经分析计算得知,继电器触头烧蚀的根本原因是动触头在机车和风道振动条件下发生共振,产生微距开合,造成烧蚀。针对触头烧蚀和异物冰雪堵塞等实际问题,设计了新型继电器。经实际验证,新结构产品完全达到了项目设计目标,运行稳定可靠,完全解决了触头过早烧蚀和冰雪异物堵塞问题,各项性能指标优良。
經分析計算得知,繼電器觸頭燒蝕的根本原因是動觸頭在機車和風道振動條件下髮生共振,產生微距開閤,造成燒蝕。針對觸頭燒蝕和異物冰雪堵塞等實際問題,設計瞭新型繼電器。經實際驗證,新結構產品完全達到瞭項目設計目標,運行穩定可靠,完全解決瞭觸頭過早燒蝕和冰雪異物堵塞問題,各項性能指標優良。
경분석계산득지,계전기촉두소식적근본원인시동촉두재궤차화풍도진동조건하발생공진,산생미거개합,조성소식。침대촉두소식화이물빙설도새등실제문제,설계료신형계전기。경실제험증,신결구산품완전체도료항목설계목표,운행은정가고,완전해결료촉두과조소식화빙설이물도새문제,각항성능지표우량。
Through analysis and calculation,the root causes of relay contact ablation were obtained.The moving contacts resonated with vibration of the locomotive and wind road,and then microspur was open and close,resulting in ablation.Aiming at several practical problems,such as relay contact ablation,ice and snow blockage,and so on,a new type of relay was designed.Actual verification proved that the products of new structure fully met the design object,and operated stably and reliably.It completely solved the issues of premature contacts ablation and ice and snow blockage,and various performance indicators were excellent.