国华太仓发电有限责任公司2×600 MWe超临界机组自试运投产以来,给水泵再循环调节阀多次发生卡涩。经多次试验、分析、治理,彻底解决了给水泵再循环调节阀卡涩现象。
國華太倉髮電有限責任公司2×600 MWe超臨界機組自試運投產以來,給水泵再循環調節閥多次髮生卡澀。經多次試驗、分析、治理,徹底解決瞭給水泵再循環調節閥卡澀現象。
국화태창발전유한책임공사2×600 MWe초림계궤조자시운투산이래,급수빙재순배조절벌다차발생잡삽。경다차시험、분석、치리,철저해결료급수빙재순배조절벌잡삽현상。
After the 2×600MWe supercritical units were put into test operation,the jam faults of the feed pump recycle adjustment valve were occurred more than once.By repeated experiments,analysis and treatments,the jam fault of the feed pump recycle adjustment valve was solved completely.