中华外科杂志
中華外科雜誌
중화외과잡지
CHINESE JOURNAL OF SURGERY
2010年
20期
1556-1560
,共5页
及松洁%周一新%李玉军%刘庆华%黄野
及鬆潔%週一新%李玉軍%劉慶華%黃野
급송길%주일신%리옥군%류경화%황야
关节成形术,置换,膝%膝关节%人工%生物力学
關節成形術,置換,膝%膝關節%人工%生物力學
관절성형술,치환,슬%슬관절%인공%생물역학
Arthroplasty,replacement,knee%Knee,prothesis%Biomechanics
目的 探讨膝关节假体垫片设计对膝关节置换术后临床功能和膝关节运动学的影响.方法 分析2007年7月至2009年6月使用GENESIS Ⅱ假体行全膝关节置换术的28例膝关节骨关节炎患者的临床资料,共42膝,平均随访27.7个月.按照使用垫片的种类分为高屈曲垫片组(男性1例,女性14例,23膝;年龄54~74岁,平均62.8岁)和标准组(男性1例,女性12例,19膝;年龄54~74岁,平均64.3岁).通过膝关节评分比较两组的临床功能.采用循环透视和软件分析的方法比较两组病例在膝关节屈伸活动时股骨后滚、伸膝装置力臂等参数,评价垫片设计对膝关节运动的影响.结果 标准组和高屈曲垫片组的术后活动度分别为120°和123°,差异无统计学意义.两组在膝关节学会评分上没有差异.高屈曲垫片组术后的Feller评分高于标准组,差异有统计学意义(P=0.012).在影像学测量上,两组病例在0~120°范围活动时股骨后滚和伸膝装置力臂的差异均无统计学意义;活动范围达到130°时,两组的伸膝装置力臂差异有统计学意义(P=0.034).结论 高屈曲垫片的改良设计在减少膝关节置换术后膝前痛的发生、改善膝关节功能方面有一定的作用;但可能会减小伸膝装置的力臂,从而影响股四头肌的做功.
目的 探討膝關節假體墊片設計對膝關節置換術後臨床功能和膝關節運動學的影響.方法 分析2007年7月至2009年6月使用GENESIS Ⅱ假體行全膝關節置換術的28例膝關節骨關節炎患者的臨床資料,共42膝,平均隨訪27.7箇月.按照使用墊片的種類分為高屈麯墊片組(男性1例,女性14例,23膝;年齡54~74歲,平均62.8歲)和標準組(男性1例,女性12例,19膝;年齡54~74歲,平均64.3歲).通過膝關節評分比較兩組的臨床功能.採用循環透視和軟件分析的方法比較兩組病例在膝關節屈伸活動時股骨後滾、伸膝裝置力臂等參數,評價墊片設計對膝關節運動的影響.結果 標準組和高屈麯墊片組的術後活動度分彆為120°和123°,差異無統計學意義.兩組在膝關節學會評分上沒有差異.高屈麯墊片組術後的Feller評分高于標準組,差異有統計學意義(P=0.012).在影像學測量上,兩組病例在0~120°範圍活動時股骨後滾和伸膝裝置力臂的差異均無統計學意義;活動範圍達到130°時,兩組的伸膝裝置力臂差異有統計學意義(P=0.034).結論 高屈麯墊片的改良設計在減少膝關節置換術後膝前痛的髮生、改善膝關節功能方麵有一定的作用;但可能會減小伸膝裝置的力臂,從而影響股四頭肌的做功.
목적 탐토슬관절가체점편설계대슬관절치환술후림상공능화슬관절운동학적영향.방법 분석2007년7월지2009년6월사용GENESIS Ⅱ가체행전슬관절치환술적28례슬관절골관절염환자적림상자료,공42슬,평균수방27.7개월.안조사용점편적충류분위고굴곡점편조(남성1례,녀성14례,23슬;년령54~74세,평균62.8세)화표준조(남성1례,녀성12례,19슬;년령54~74세,평균64.3세).통과슬관절평분비교량조적림상공능.채용순배투시화연건분석적방법비교량조병례재슬관절굴신활동시고골후곤、신슬장치역비등삼수,평개점편설계대슬관절운동적영향.결과 표준조화고굴곡점편조적술후활동도분별위120°화123°,차이무통계학의의.량조재슬관절학회평분상몰유차이.고굴곡점편조술후적Feller평분고우표준조,차이유통계학의의(P=0.012).재영상학측량상,량조병례재0~120°범위활동시고골후곤화신슬장치역비적차이균무통계학의의;활동범위체도130°시,량조적신슬장치역비차이유통계학의의(P=0.034).결론 고굴곡점편적개량설계재감소슬관절치환술후슬전통적발생、개선슬관절공능방면유일정적작용;단가능회감소신슬장치적역비,종이영향고사두기적주공.
Objective To investigate the influence of the insert design of knee prosthesis on clinical results and kinematics of the knee after total knee arthroplasty (TKA). Methods Forty-two knees in 28 patients with knee osteoarthritis undergoing TKA using the GENESIS Ⅱ from July 2007 to June 2009 were included in this study, mean follow-up of 27.7 months. The cases were divided into 2 groups according to the type of insert, one was high flexion insert group (23 knees) and the other was standard insert group (19 knees). Two groups were compared by clinical ratings of knee function. The motion of flexion and extension of the two groups was observed by cyclic fluoroscopy and the data was analyzed by mapping software. The influence of the insert design of knee prosthesis on kinematics of the knee after TKA was investigated by comparing the parameters of the two groups during the movement of knee joint, including femoral roll back and extensor mechanism arm. Results The range of motion of standard insert group and high flexion insert group was 120° and 123° respectively with no difference between them. There was no difference of knee society clinical rating system in both groups. Feller score of high flexion insert group was higher than the standard insert group, the difference was significant statistically (P =0.012). In the imaging measurement, the two groups had no differences in femoral rollback and extensor mechanism arm during the 0 to 120° range of movement. The two groups appeared significant statistically (P = 0.034) in the extensor mechanism arm when flexion extended to 130°. Conclusions The high flexion improved design may play a certain role on reducing anterior knee pain and improving knee function after TKA. However, the improved design may be reduced the extensor mechanism arm when high flexion, so that affecting the work ablility of quadriceps.