目的 评价前瞻性心电门控64层CT冠状动脉成像的可行性和临床应用价值.方法 60例患者进行前瞻性心电门控64层CT冠状动脉成像检查,分析有效辐射剂量,并采用多平面重组(MPR)、最大密度投影(MIP)、曲面重组(CPR)及容积再现(VR)技术显示冠状动脉,评价其成像质量.结果 平均辐射剂量(2.7±0.2)mSv;符合诊断标准的冠状动脉节段为93.3%(720/772),44.2%(341/772)质量优秀,49.1%(379/772)质量中等,6.7%(52/772)质量较差.冠状动脉重度狭窄(>75%)或闭塞5例(8.3%),中度狭窄(50%~75%)17例(28.4%),管腔不规则或轻度狭窄(<50%)18例(30.0%),冠状动脉正常者20例(33.3%).结论 前瞻性心电门控64层CT冠状动脉成像的影像质量能达到诊断标准,大大降低了辐射剂量,具有很好的临床应用价值.
目的 評價前瞻性心電門控64層CT冠狀動脈成像的可行性和臨床應用價值.方法 60例患者進行前瞻性心電門控64層CT冠狀動脈成像檢查,分析有效輻射劑量,併採用多平麵重組(MPR)、最大密度投影(MIP)、麯麵重組(CPR)及容積再現(VR)技術顯示冠狀動脈,評價其成像質量.結果 平均輻射劑量(2.7±0.2)mSv;符閤診斷標準的冠狀動脈節段為93.3%(720/772),44.2%(341/772)質量優秀,49.1%(379/772)質量中等,6.7%(52/772)質量較差.冠狀動脈重度狹窄(>75%)或閉塞5例(8.3%),中度狹窄(50%~75%)17例(28.4%),管腔不規則或輕度狹窄(<50%)18例(30.0%),冠狀動脈正常者20例(33.3%).結論 前瞻性心電門控64層CT冠狀動脈成像的影像質量能達到診斷標準,大大降低瞭輻射劑量,具有很好的臨床應用價值.
목적 평개전첨성심전문공64층CT관상동맥성상적가행성화림상응용개치.방법 60례환자진행전첨성심전문공64층CT관상동맥성상검사,분석유효복사제량,병채용다평면중조(MPR)、최대밀도투영(MIP)、곡면중조(CPR)급용적재현(VR)기술현시관상동맥,평개기성상질량.결과 평균복사제량(2.7±0.2)mSv;부합진단표준적관상동맥절단위93.3%(720/772),44.2%(341/772)질량우수,49.1%(379/772)질량중등,6.7%(52/772)질량교차.관상동맥중도협착(>75%)혹폐새5례(8.3%),중도협착(50%~75%)17례(28.4%),관강불규칙혹경도협착(<50%)18례(30.0%),관상동맥정상자20례(33.3%).결론 전첨성심전문공64층CT관상동맥성상적영상질량능체도진단표준,대대강저료복사제량,구유흔호적림상응용개치.
Objective To evaluate the feasibility of prospective electrocardiogram(ECG)-gating computed tomography coronary angiography(CTCA).Methods Sixty patients with suspected or known coronary artery disease underwent 64-slice CTCA using prospective ECG-gating.Multi-planar reconstruction (MPR),curved-planar reconstruction(CPR),maximum intensity projection(MIP)and volume rendering (VR)were used to demonstrate the coronary arteries.The image quality and radiation dose was evaluated.Results The mean effective radiation dose was(2.7±0.2)mSv.93.3%(720/772)segments of all coronary arteries were of diagnostic image quality,44.2%(341/772)Was classified as excellent and 49.1%(379/772)was good.Non-diagnostic coronary segments were found in 6.7%(52/772)of all coronary arteries.Therewere 5(8.3%)cases with severe coronary stenosis(>75%)or occlusion,17(28.4%)cases with moderate stenosis(50%-75%),18(30.0%)cases with mild stenosis(<50%)or irregular lumen,20(33.3%)cases with normal coronary artery.Conclusion With a low radiation dose,prospective electrocardiogram(ECG)-gated coronary 64-MSCT angiography has a good potential for the detection of coronary stenosis,especially for excluding coronary artery disease.