中国纤检
中國纖檢
중국섬검
CHINA FIBER INSPECTION
2011年
18期
58-61
,共4页
测定%气相色谱法%纺织品助剂%五氯苯酚%水蒸气蒸馏
測定%氣相色譜法%紡織品助劑%五氯苯酚%水蒸氣蒸餾
측정%기상색보법%방직품조제%오록분분%수증기증류
testing%gas chromatography%extile auxiliaries%pentachlorophenol%steam distillation
采用气相色谱-电子俘获检测器法(GC.ECD),测定及验证纺织品中五氟苯酚的含量。用水蒸气蒸馏提取试样,提取液经乙酸酐乙酰化后以正己烷提取,用气相色谱-电子俘获检测器(GC.ECD)测定,外标法定量。通过优化,本方法平均回收率为88.2%~102.1%,精密度为8.0%~9.2%,方法测定低限为10μg/kg。各项指标均满足有关要求。
採用氣相色譜-電子俘穫檢測器法(GC.ECD),測定及驗證紡織品中五氟苯酚的含量。用水蒸氣蒸餾提取試樣,提取液經乙痠酐乙酰化後以正己烷提取,用氣相色譜-電子俘穫檢測器(GC.ECD)測定,外標法定量。通過優化,本方法平均迴收率為88.2%~102.1%,精密度為8.0%~9.2%,方法測定低限為10μg/kg。各項指標均滿足有關要求。
채용기상색보-전자부획검측기법(GC.ECD),측정급험증방직품중오불분분적함량。용수증기증류제취시양,제취액경을산항을선화후이정기완제취,용기상색보-전자부획검측기(GC.ECD)측정,외표법정량。통과우화,본방법평균회수솔위88.2%~102.1%,정밀도위8.0%~9.2%,방법측정저한위10μg/kg。각항지표균만족유관요구。
This method is feasible to determine and confirm contents of pentachlorophenol in textile auxiliaries via GC-ECD method. The testing samples are extracted by steam distillation ,the extract solution are extracted with n-hexane by acetic anhydride acetylization .Determination and confirmation is made by GC-ECD (gas-chromatography with an electron capture detector), using extermal standard method. Through the optimization ,the experimental data show tha :the corresponding recovery is 88.2%- 102.1%, the precision is 8.0%-9.2%, and the limit of determination is 10μ/kg .All the technical items conform to the requirements.