目的 探讨应用流式细胞技术测定眼部常见真菌对抗真菌药物敏感性的可行性.方法 用流式细胞术药敏试验(Flow Cytometry Susceptibility Testing,FCST)和标准药敏试验(肉汤稀释法M38-A)法检测1株标准镰刀菌和23株临床镰刀菌对两性霉素B(AMB)的敏感性.FCST法以碘化丙啶(PI)为染料,真菌与各浓度药物孵育3h后检洲各管平均荧光强度(MFI),最低抑菌浓度(MIC)定义为相于生长对照管MFI增加50%时的最低药物浓度.结果 两种检测方法有8株真菌的MIC完全相同,12株相差1个倍比稀释度,2株相差2个倍比稀释度,在1个稀释度范围内两种检测方法的一致性为83.3%,2个稀释度范围的一致性为91.6%.两组结果无统计学差异(P=0.5685).结论 FCST法检测眼部镰刀菌对抗真菌药物的敏感性所得结果与标准法所得结果有良好的一致性,且FCST法具有快速、敏感、准确的优势,是临床检测丝状菌药物敏感性较具发展潜力的一种新方法.
目的 探討應用流式細胞技術測定眼部常見真菌對抗真菌藥物敏感性的可行性.方法 用流式細胞術藥敏試驗(Flow Cytometry Susceptibility Testing,FCST)和標準藥敏試驗(肉湯稀釋法M38-A)法檢測1株標準鐮刀菌和23株臨床鐮刀菌對兩性黴素B(AMB)的敏感性.FCST法以碘化丙啶(PI)為染料,真菌與各濃度藥物孵育3h後檢洲各管平均熒光彊度(MFI),最低抑菌濃度(MIC)定義為相于生長對照管MFI增加50%時的最低藥物濃度.結果 兩種檢測方法有8株真菌的MIC完全相同,12株相差1箇倍比稀釋度,2株相差2箇倍比稀釋度,在1箇稀釋度範圍內兩種檢測方法的一緻性為83.3%,2箇稀釋度範圍的一緻性為91.6%.兩組結果無統計學差異(P=0.5685).結論 FCST法檢測眼部鐮刀菌對抗真菌藥物的敏感性所得結果與標準法所得結果有良好的一緻性,且FCST法具有快速、敏感、準確的優勢,是臨床檢測絲狀菌藥物敏感性較具髮展潛力的一種新方法.
목적 탐토응용류식세포기술측정안부상견진균대항진균약물민감성적가행성.방법 용류식세포술약민시험(Flow Cytometry Susceptibility Testing,FCST)화표준약민시험(육탕희석법M38-A)법검측1주표준렴도균화23주림상렴도균대량성매소B(AMB)적민감성.FCST법이전화병정(PI)위염료,진균여각농도약물부육3h후검주각관평균형광강도(MFI),최저억균농도(MIC)정의위상우생장대조관MFI증가50%시적최저약물농도.결과 량충검측방법유8주진균적MIC완전상동,12주상차1개배비희석도,2주상차2개배비희석도,재1개희석도범위내량충검측방법적일치성위83.3%,2개희석도범위적일치성위91.6%.량조결과무통계학차이(P=0.5685).결론 FCST법검측안부렴도균대항진균약물적민감성소득결과여표준법소득결과유량호적일치성,차FCST법구유쾌속、민감、준학적우세,시림상검측사상균약물민감성교구발전잠력적일충신방법.
Objective To investigate the possibility of determination of the susceptibility of ocular fusarium isolates to anti-fungal drugs by Flow Cytometry.Methods The sensitivity to amphotericin B (AMB)of one standard strain and 23 clinical isolates of fusarium were examined both with Flow Cytometry Susceptibility test (FCST)and broth microdilution method M38-A.In FCST the mean fluorescence intensity (MFI)of the samples was tested after 3 hours' incubation with various concentrations of the drug by using pro-pidium iodide(PI)as a fluorescent probe.The minimal inhibitory concentration(MIC)was defined as the lowest concentration of drug that produced a 50% increase in MFI compared to that of the growth control.Results MIC values showed 83.3 % agreement within one drug dilution between the FCST and broth microdilution method and 91.6 % agreement within two drug dilutions.Paired t test values were not statistically significant(P =0.5685 ).Conclusion The MICs obtained by FCST for all ocular fusarium were in good agreement of the re-sults of the broth microdilution method.Flow Cytometry susceptibility test is a rapid,accurate and sensitive method in antifungal mean fluorescence intensity testing of mycelial fungus.