背景:运动伪影及磁敏感伪影严重影响MR成像质量,Propeller技术采用填充模式,以辐射状的叶片用螺旋的方式采集数据,在很大程度上解决了运动伪影及磁敏感伪影的问题.目的:探讨Propeller技术在头部伪影消除的应用价值.设计、时间及地点:对比观察实验,于2006-0712007-04在解放军成都军区昆明总医院完成.参试者:21例磁共振头颅日常检查中出现躁动或不能自控患者,5例固定义齿致磁敏感伪影明显者.方法:对21例磁共振头颅日常检查躁动或不能自控患者,常规T2FRFSE序列运动伪影明显,用Propeller技术进行T2WI扫描并进行对比;5例常规扩散加权图像序列磁敏感伪影明显者进行Propeller扩散加权图像扫描并进行对比.主要观察指标:Propeller技术应用后运动伪影与磁敏感伪影的改变情况.结果:21例应用Propeller技术进行T2WI扫描明显减少或消除了运动伪影,5例Propeller扩敞加权图像明显消除磁敏感效应引起的伪影.均生成较满意图像.结论:应用Propeller T2WI及扩散加权图像成像技术可以明显减少或消除患者因运动及磁敏感效应造成的伪影,显著提高图像质量,获得具有临床诊断价值的理想图像.
揹景:運動偽影及磁敏感偽影嚴重影響MR成像質量,Propeller技術採用填充模式,以輻射狀的葉片用螺鏇的方式採集數據,在很大程度上解決瞭運動偽影及磁敏感偽影的問題.目的:探討Propeller技術在頭部偽影消除的應用價值.設計、時間及地點:對比觀察實驗,于2006-0712007-04在解放軍成都軍區昆明總醫院完成.參試者:21例磁共振頭顱日常檢查中齣現躁動或不能自控患者,5例固定義齒緻磁敏感偽影明顯者.方法:對21例磁共振頭顱日常檢查躁動或不能自控患者,常規T2FRFSE序列運動偽影明顯,用Propeller技術進行T2WI掃描併進行對比;5例常規擴散加權圖像序列磁敏感偽影明顯者進行Propeller擴散加權圖像掃描併進行對比.主要觀察指標:Propeller技術應用後運動偽影與磁敏感偽影的改變情況.結果:21例應用Propeller技術進行T2WI掃描明顯減少或消除瞭運動偽影,5例Propeller擴敞加權圖像明顯消除磁敏感效應引起的偽影.均生成較滿意圖像.結論:應用Propeller T2WI及擴散加權圖像成像技術可以明顯減少或消除患者因運動及磁敏感效應造成的偽影,顯著提高圖像質量,穫得具有臨床診斷價值的理想圖像.
배경:운동위영급자민감위영엄중영향MR성상질량,Propeller기술채용전충모식,이복사상적협편용라선적방식채집수거,재흔대정도상해결료운동위영급자민감위영적문제.목적:탐토Propeller기술재두부위영소제적응용개치.설계、시간급지점:대비관찰실험,우2006-0712007-04재해방군성도군구곤명총의원완성.삼시자:21례자공진두로일상검사중출현조동혹불능자공환자,5례고정의치치자민감위영명현자.방법:대21례자공진두로일상검사조동혹불능자공환자,상규T2FRFSE서렬운동위영명현,용Propeller기술진행T2WI소묘병진행대비;5례상규확산가권도상서렬자민감위영명현자진행Propeller확산가권도상소묘병진행대비.주요관찰지표:Propeller기술응용후운동위영여자민감위영적개변정황.결과:21례응용Propeller기술진행T2WI소묘명현감소혹소제료운동위영,5례Propeller확창가권도상명현소제자민감효응인기적위영.균생성교만의도상.결론:응용Propeller T2WI급확산가권도상성상기술가이명현감소혹소제환자인운동급자민감효응조성적위영,현저제고도상질량,획득구유림상진단개치적이상도상.
BACKGROUND: Motion artifacts and magnetic susceptibility artifacts have serious impacts on magnetic resonance (MR) image quality. Periodically rotated overlapping parallel lines with enhanced reconstruction (Propeller) technique, collecting data spirally using radial blades by filling pattern, greatly reduce or eliminate these artifacts.OBJECTIVE: To discuss the clinical application of MR Propeller technique in eliminating the artifacts of brain images.DESIGN, TIME AND SETTING: The comparative observation was performed at Kunming General Hospital of Chengdu Military Area Command of Chinese PLA from July 2006 to April 2007.PARTICIPANTS: Twenty-one cases showed dysphoria or unable to control oneself in the routine cranial MRI examination, and 5 presented artifacts because of magnetic-susceptibility.METHODS: Twenty-one cases, who had dysphoria and could not control themselves in routine cranial MRI examination, underwent Propeller T2 weighted imaging (WI), and the images were compared with routine T2 fast-recovery fast spin echo sequence; 5 cases, who had artifacts because of magnetic-susceptibility, received Propeller diffusion weighted imaging (DWI), and the images were compared with routine DWI.MAIN OUTCOME MEASURES: The changes of motion artifacts and magnetic susceptibility artifacts resulted from Propeller technique.RESULTS: The artifacts caused by motion in 21 cases were significantly reduced or eliminated by Propeller T2WI scanning, and those caused by magnetic susceptibility in the other 5 cases were also significantly eliminated by Propeller DWI. Satisfactory MR images were obtained.CONCLUSION: Propeller T2WI or DWI technique can obviously reduce or eliminate the artifacts caused by motion or magnetic-susceptibility, and can significantly improve the image quality for clinical diagnosis.