中华物理医学与康复杂志
中華物理醫學與康複雜誌
중화물리의학여강복잡지
CHINESE JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION
2011年
6期
425-430
,共6页
伊文超%胡建平%励建安%蒋祥龙%宗敏%穆西虎%金鸿%赵正恩
伊文超%鬍建平%勵建安%蔣祥龍%宗敏%穆西虎%金鴻%趙正恩
이문초%호건평%려건안%장상룡%종민%목서호%금홍%조정은
关节角度%关节活动度%关节中心%三点法%四点法
關節角度%關節活動度%關節中心%三點法%四點法
관절각도%관절활동도%관절중심%삼점법%사점법
Joint angle%Joint range of motion%Joint center%Three-point method%Four-point method
目的 比较膝关节角度三点测量法与四点测量法的信度和效度.方法 无膝关节运动障碍者25例,在膝关节处于伸直、小角度屈曲及大角度屈曲3种位置进行三点法和四点法角度测量,拍摄X线片作为金标准.采用Bland-altman法(95%一致性区间,LOA)进行信度和效度分析.结果 关节轴心随角度变化而位移.信度(95%LOA):测量者间四点法(-5.0,2.7),三点法(-6.5,4.4);测量者内四点法A(-3.6,4.0)、B(-4.1,4.8),三点法A(-5.0,6.4)、B(-6.1,5.8).效度(95%LOA):3种关节位置测量四点法分别为(3.5,2.6)、(-3.3,3.6)和(-1.9,5.7);三点法分别为(6.8,1.1)、(-4.0,7.1)和(0,8.5).结论 关节角度测量轴心随角度变化而移位,四点法的信度和效度优于传统三点法.
目的 比較膝關節角度三點測量法與四點測量法的信度和效度.方法 無膝關節運動障礙者25例,在膝關節處于伸直、小角度屈麯及大角度屈麯3種位置進行三點法和四點法角度測量,拍攝X線片作為金標準.採用Bland-altman法(95%一緻性區間,LOA)進行信度和效度分析.結果 關節軸心隨角度變化而位移.信度(95%LOA):測量者間四點法(-5.0,2.7),三點法(-6.5,4.4);測量者內四點法A(-3.6,4.0)、B(-4.1,4.8),三點法A(-5.0,6.4)、B(-6.1,5.8).效度(95%LOA):3種關節位置測量四點法分彆為(3.5,2.6)、(-3.3,3.6)和(-1.9,5.7);三點法分彆為(6.8,1.1)、(-4.0,7.1)和(0,8.5).結論 關節角度測量軸心隨角度變化而移位,四點法的信度和效度優于傳統三點法.
목적 비교슬관절각도삼점측량법여사점측량법적신도화효도.방법 무슬관절운동장애자25례,재슬관절처우신직、소각도굴곡급대각도굴곡3충위치진행삼점법화사점법각도측량,박섭X선편작위금표준.채용Bland-altman법(95%일치성구간,LOA)진행신도화효도분석.결과 관절축심수각도변화이위이.신도(95%LOA):측량자간사점법(-5.0,2.7),삼점법(-6.5,4.4);측량자내사점법A(-3.6,4.0)、B(-4.1,4.8),삼점법A(-5.0,6.4)、B(-6.1,5.8).효도(95%LOA):3충관절위치측량사점법분별위(3.5,2.6)、(-3.3,3.6)화(-1.9,5.7);삼점법분별위(6.8,1.1)、(-4.0,7.1)화(0,8.5).결론 관절각도측량축심수각도변화이이위,사점법적신도화효도우우전통삼점법.
Objective To study the clinical value of using a four-point method (FP) in measuring joint angles.Method Methods Twenty-five subjects without knee dysfunction were studied.Every knee joint was tested in extension,below 90° of flexion and above 90° of flexion with the traditional three-point method (TP) and the new four-point method.X-rays were taken as a gold standard measurement.The reliability and validity were analyzed using Bland-Altman plots,which can yield 95% limits of agreement (LOA).Results (1) The joint axis centers moved with changes in joint angle.(2) The 95% LOA of inter-tester reliability was (-5.0,2.7) with the FP and (-6.5,4.4) with the TP.The 95% LOAs of intra-tester reliability were (-3.6,4.0) for tester A and (-4.1,4.8) for tester B with the FP,while (-5.0,6.4) for tester A and (-6.1,5.8) for tester B with the TP.(3) The 95% LOAs in the three positions were (3.5,2.6) in extension,(-3.3,3.6) in mild flexion and (-1.9,5.7) in greater flexion with the FP,and ( 6.8,1.1),(-4.0,7.1) and (0,8.5) with the TP.Conclusions The FP gives better reliability and validity than the TP in joint angle measurement.