哈尔滨工业大学学报(英文版)
哈爾濱工業大學學報(英文版)
합이빈공업대학학보(영문판)
JOURNAL OF HARBIN INSTITUTE OF TECHNOLOGY
2004年
3期
305-308
,共4页
孟克%潘玉衡%安翠珍%王东红
孟剋%潘玉衡%安翠珍%王東紅
맹극%반옥형%안취진%왕동홍
polarization%interference%hydrophone%measurement
Some optical fiber hydrophones, such as PGC Mach-Zehnder Interferometer, have a birefringence of single mode optical fibers which induce signal fading. Especially, if two optical beams from the optical arms are orthogonal, the interferomic signal can' t be detected at all. Here a new method is introduced. This is to translate the detected phase difference into a linearly polarized angle, then detect it, so that polarization inducing signal fading will be avoided. In theory, this problem is solved. Furthermore, the effect on measurement results from optical source fluctuation becomes little when using the polarization technique.