目的 探讨左室扭转评价移植心脏左心室功能的价值.方法 30例心脏移植受者,17例正常人,应用二维应变软件测量左室基底部和心尖部旋转角度、整体扭转角度及达峰时间,计算解旋率,比较两组间差异,并分析其与舒张末期、收缩末期容积及射血分数之间的关系.结果 移植组心尖部旋转角度及整体扭转角度均小于对照组.扭转角度与收缩末容积呈负相关,与射血分数呈正相关.两组间解旋率无明显差异.结论 二维斑点追踪技术可以准确反映左室扭转运动,为移植心脏左室收缩功能的整体判断提供重要的依据.
目的 探討左室扭轉評價移植心髒左心室功能的價值.方法 30例心髒移植受者,17例正常人,應用二維應變軟件測量左室基底部和心尖部鏇轉角度、整體扭轉角度及達峰時間,計算解鏇率,比較兩組間差異,併分析其與舒張末期、收縮末期容積及射血分數之間的關繫.結果 移植組心尖部鏇轉角度及整體扭轉角度均小于對照組.扭轉角度與收縮末容積呈負相關,與射血分數呈正相關.兩組間解鏇率無明顯差異.結論 二維斑點追蹤技術可以準確反映左室扭轉運動,為移植心髒左室收縮功能的整體判斷提供重要的依據.
목적 탐토좌실뉴전평개이식심장좌심실공능적개치.방법 30례심장이식수자,17례정상인,응용이유응변연건측량좌실기저부화심첨부선전각도、정체뉴전각도급체봉시간,계산해선솔,비교량조간차이,병분석기여서장말기、수축말기용적급사혈분수지간적관계.결과 이식조심첨부선전각도급정체뉴전각도균소우대조조.뉴전각도여수축말용적정부상관,여사혈분수정정상관.량조간해선솔무명현차이.결론 이유반점추종기술가이준학반영좌실뉴전운동,위이식심장좌실수축공능적정체판단제공중요적의거.
Objective To evaluate the value of left ventricular (LV) torsion for assessing left ventricular function in adult heart transplant patients using two-dimensional speckle tracking imaging.Methods Basal and apical LV short-axis view and apical LV long-axis view of two-demensional images were acquired in 30 heart transplant patients and 17 healthy volunteers. Using two-dimensional strain software,LV basal and apical rotation versus time profiles were obtained at their short-axis level respectively. LV torsion was defined as apical rotation relative to the base, so the LV torsion versus time profiles could be drawn. LV basal rotation,apical rotation,global torsion and their time to peak were respectively measured,and the rate of LV untwisting was calculated. Statistical analysis was used to find the difference between the two groups and to investigate the relationship between LV torsion or the rate of LV untwisting and echocardiographic parameters. Results LV apical rotation and LV global torsion in heart transplant group were significantly lower than those in normal group. LV global torsion inversely correlated with LV end systolic volume,positively with LV ejection fraction. There was no significant difference between the two groups in the rate of LV untwisting. The rate of LV untwisting didn't correlate with echocardiographic parameters. Conclusions LV torsion can be measured exactly by two-dimensional speckle tracking imaging, it can be used to quantify LV global systolic function in heart transplant patients.