资源调查与环境
資源調查與環境
자원조사여배경
RESOURCES SURVEY & ENVIRONMENT
2011年
4期
307-310
,共4页
蔡述伟%朱家平%王爱华%李华玲
蔡述偉%硃傢平%王愛華%李華玲
채술위%주가평%왕애화%리화령
不确定度%双误差拟合%电感耦合等离子体发射光谱%锰%地下水
不確定度%雙誤差擬閤%電感耦閤等離子體髮射光譜%錳%地下水
불학정도%쌍오차의합%전감우합등리자체발사광보%맹%지하수
uncertainty%double error fitting%ICP-AES%manganese contents%groundwater
本文对电感耦合等离子体发射光谱法测定地下水中锰含量的不确定度进行了评定,标准曲线采用双误差拟合法,建立了不确定度评定模型,对测定地下水样品中锰含量的不确定度作了评估。
本文對電感耦閤等離子體髮射光譜法測定地下水中錳含量的不確定度進行瞭評定,標準麯線採用雙誤差擬閤法,建立瞭不確定度評定模型,對測定地下水樣品中錳含量的不確定度作瞭評估。
본문대전감우합등리자체발사광보법측정지하수중맹함량적불학정도진행료평정,표준곡선채용쌍오차의합법,건립료불학정도평정모형,대측정지하수양품중맹함량적불학정도작료평고。
The uncertainty of determination of manganese contents in groundwater by inductively coupled plasma atomic emission spectrometry(ICP-AES) was evaluated in this paper.The calculating model of double error fitting in the course of standard curve fitting was used,and the mathematical evaluation model for uncertainty was also established.In addition,the uncertainty of the determination of manganese contents in groundwater samples was evaluated.