原子与分子物理学报
原子與分子物理學報
원자여분자물이학보
CHINESE JOURNAL OF ATOMIC AND MOLECULAR PHYSICS
2010年
1期
107-112
,共6页
赵芳%李润华%周伦彬%陆林轩%王自鑫%周建英
趙芳%李潤華%週倫彬%陸林軒%王自鑫%週建英
조방%리윤화%주륜빈%륙림헌%왕자흠%주건영
激光诱导击穿光谱%油漆%有害重金属%快速定量分析
激光誘導擊穿光譜%油漆%有害重金屬%快速定量分析
격광유도격천광보%유칠%유해중금속%쾌속정량분석
laser-induced breakdown spectroscopy%paint%toxic heavy metal%rapid and quantitative analysis
很多轻工业产品需要用到油性油漆,其中的重金属元素的含量是否超标将会直接影响到产品质量及其安全性.因此发展轻工产品中重金属含量的快速检测技术,对促进国民经济的发展和保障消费者生命安全具有重要的意义.我们利用激光诱导击穿光谱技术实现了对油漆中有害重金属含量的快速定性和定量分析.通过观测激光等离子体中重金属原子辐射强度可以定性测量重金属含量的大体水平.然后,在相同检测条件下,将已知浓度的标准样品作为参考,制定出各元素的校正曲线,使用外标法,就能够实现定量分析.对Pb、Cr、Cd三种有害重金属元素,目前检出限分别达到9、3.5和23 ppm的水平,分析相对误差小于10%,单次测量时间短于2分钟.汞的结果不太理想,检测灵敏度相对偏低,与其原子辐射寿命较短有关.我们将采取脉冲放电延长汞原子辐射弛豫时间的措施来改进汞元素的分析灵敏度,使其达到较高水平.
很多輕工業產品需要用到油性油漆,其中的重金屬元素的含量是否超標將會直接影響到產品質量及其安全性.因此髮展輕工產品中重金屬含量的快速檢測技術,對促進國民經濟的髮展和保障消費者生命安全具有重要的意義.我們利用激光誘導擊穿光譜技術實現瞭對油漆中有害重金屬含量的快速定性和定量分析.通過觀測激光等離子體中重金屬原子輻射彊度可以定性測量重金屬含量的大體水平.然後,在相同檢測條件下,將已知濃度的標準樣品作為參攷,製定齣各元素的校正麯線,使用外標法,就能夠實現定量分析.對Pb、Cr、Cd三種有害重金屬元素,目前檢齣限分彆達到9、3.5和23 ppm的水平,分析相對誤差小于10%,單次測量時間短于2分鐘.汞的結果不太理想,檢測靈敏度相對偏低,與其原子輻射壽命較短有關.我們將採取脈遲放電延長汞原子輻射弛豫時間的措施來改進汞元素的分析靈敏度,使其達到較高水平.
흔다경공업산품수요용도유성유칠,기중적중금속원소적함량시부초표장회직접영향도산품질량급기안전성.인차발전경공산품중중금속함량적쾌속검측기술,대촉진국민경제적발전화보장소비자생명안전구유중요적의의.아문이용격광유도격천광보기술실현료대유칠중유해중금속함량적쾌속정성화정량분석.통과관측격광등리자체중중금속원자복사강도가이정성측량중금속함량적대체수평.연후,재상동검측조건하,장이지농도적표준양품작위삼고,제정출각원소적교정곡선,사용외표법,취능구실현정량분석.대Pb、Cr、Cd삼충유해중금속원소,목전검출한분별체도9、3.5화23 ppm적수평,분석상대오차소우10%,단차측량시간단우2분종.홍적결과불태이상,검측령민도상대편저,여기원자복사수명교단유관.아문장채취맥충방전연장홍원자복사이예시간적조시래개진홍원소적분석령민도,사기체도교고수평.
Oil paints are used on many light industrial products. The concentration of heavy metals in paints is one of critical standards for quality control of the products and their safeties for use. To develop a rapid and quantitative analysis technique for detection of heavy metals in light industrial products is very important for economy development and ensuring their safeties for use. A rapid, both qualitative and quantitative analysis method of toxic heavy metals in paints with laser-induced breakdown spectroscopy (LIBS) was developed. By observing atomic emission intensities from paints samples, the concentrations of heavy metals can be qualitatively estimated. A quantitative analysis can be realized by using external standard method, while the calibration curves are determined using a few reference samples in which the concentrations of heavy metals are known and are measured under the same experimental conditions. The limits of detection of Pb, Cr and Cd were determined to be 9, 3.5 and 23ppm, respectively. Relative measure error is less than 10% and the time required for single measurement is 2 minutes. The results of mercury are not good at the moment. Its detection sensitivity is relatively poor due to its short lifetime of the upper state corresponding to the analysis line. It is planed to enhance the detection sensitivity of mercury in our laboratory by using pulsed discharge to extend the decay time of mercury atomic emission.